Work

PERFORMANCE OF a PACKED LIQUID-LIQUID EXTRACTION COLUMN ; DOLGULU BİR EKSTRAKSİYON KOLONUNUN PERFORMANSI

Year: 1999
Type: article
Abstract: The influence of feed ratios ((LE/LR) ) on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system composed of water + propionic acid + trichloroethylene was used. The data used to triangular diagram were obtained experimentally. The overall mass transfer coefficients, the numbers of overall mass transfer units, the heights of mass transfer units, the numbers of theoretical stages and height equivalent to a theoretical stage (H. E. T. S.) values were calculated and compared with each other.
Language: English
Open Access status: diamond
OpenAlex ID: W1550641488
FWCI:
Cites: 10
Cited by:
Related to: 8