Étude de l’impact de l’incertitude des processus de reconstruction 3D et de recalage sur l’analyse de la cinématique du genou
Year: 2018
Type: dissertation
Abstract: Knee kinematic analysis is used to evaluate the mobility of patients. This evaluation is performed by comparing movement characteristics between each movement acquisition. However, variations of those characteristics may be due to a change in motion during acquisition, to measurement errors or to modeling errors. Thus, distinguishing the sources of these variations would allow clinicians to minimize the risk of misinterpretation. This master project aims to address the data errors from the data acquisition process itself. Focusing on real-time knee anatomical movement visualization processes, this project is centered on the kinematic and morphological data acquisition. Thus, 3D bone reconstruction and registration steps will be critical steps in the acquisitions. This project studies 3D reconstruction and registration step precision impact on data acquired inaccuracy. Also, this project suggests a data inaccuracies integration in their real-time visualization. A knee joint movement simulator developed by the collaborative company has allows to obtain kinematic data of the knee movement. These data were processed by a movement decomposition into six degrees of freedom. Kinematic data acquisition inaccuracy is simulated by a Monte Carlo method. Twenty-four parameters determining 3D reconstruction and registration steps inaccuracy were studied. A link between acquisition process inaccuracy and knee kinematic quantification is established by mathematical equation from cross-validation and step-by-step regression. A user interface has been implemented to illustrate characterization results with their inaccuracies. Monte Carlo method and modeling indicate that knee kinematic analysis errors by the decomposition in six degrees of freedom of movement are strongly correlated with registration step inaccuracy values (correlation coefficients maximum is 0.85). The 3D reconstruction step inaccuracies are less correlated to error values. This study highlights the importance of registration step resolution. In addition, it validates current practices in 3D reconstruction used by the whole scientific community. Indeed, 3D reconstruction impact on knee kinematic analysis is minimized by the use of points resulting from geometrical shapes registred on 3D reconstruction parts, opposed to points acquired individually. Therefore, it would be relevant to carry out further studies on inaccuracy reduction of the registration step.
Author: Anaëlle Nedelec
Institutions: Polytechnique Montréal, Université de Montréal
Language: French
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2904051520
