Work

Design and specification so that 21st century reinforced concrete structures won't corrode so soon

Year: 2013
Type: conference-paper
Abstract: The durability of reinforced concrete structures is affected by a number of factors such as environmental exposure, electrochemical reactions, mechanical loading, impact damage and others.Of all of these, corrosion of the reinforcement is probably the main cause for the deterioration of steel reinforced concrete structures.Corrosion management is becoming increasingly necessary as a result of the growing number of aging infrastructure assets (e.g.bridges, tunnels etc.) and the increased requirement for unplanned maintenance in order to keep these structures operational throughout their design life (and frequently, beyond).A recently completed research programme by the authors investigated the long-term performance of the most common corrosion management techniques by means of in-situ and laboratory testing, and focused on full-scale bridge structures in order to collect rigorous empirical data.This was consequently analysed in order to establish improvements for the corrosion management of steel reinforced concrete structures through changes in design, specification and maintenance requirements.This paper provides an overarching review of how the findings of this research could be applied by industry in order to enhance the durability and hence extend the service life of reinforced concrete structures.
Language: English
Open Access status: green
OpenAlex ID: W2910667993
FWCI:
Cites: 7
Cited by:
Related to: 9