Tribological, Electrochemical, and Tribocorrosion Behaviour of New Titanium Biomedical Alloys
Year: 2018
Type: dissertation
Abstract: Second-generation titanium biomaterials, β titanium alloys, particularly vanadium free titanium alloys, have become a focus of research due to their potential application in biomedical fields.Therefore, there is currently considerable interest in the tribocorrosion response of these alloys.In the present work, a systematic study has been completed to investigate and understand the degradation resulting from electrochemistry (corrosion) and mechanical (wear) in a range of vanadium free titanium alloys in 25vol% bovine calf serum.Five different based titanium-based alloys, namely Ti-Mo8-Nb4-Zr2, Ti-Mo8-Nb6-Zr4, Ti-Mo8-Nb4-Zr5, Ti-Ta30, and Ti-Ta27-Al5 alloys (at%) were prepared using a non-consumable arc-melting furnace with inert argon atmosphere.Alloys were arc melted, homogenized, cold rolled and finally subjected to solution heat treatment and then quenched in water.Commercially pure titanium Cp-Ti with an α-phase microstructure and Ti-6Al-4V with α+βphase microstructure was tested for comparison.Alloys were characterized before testing.Alloys were successfully fabricated using ingot metallurgy, including the Ti-Ta30 alloy.The alloys exhibited excellent cold workability, except the Ti-Ta30 alloy which needed an intermediate annealing treatment during thermo-mechanical treatment to increase the cold workability.XRD and microstructural analysis showed that the alloys except the Ti-Ta27-Al5 consisted of single phase β.All alloys had a lower elastic modulus than that of Cp-Ti and Ti-6Al-4V and had average Vickers micro-hardness values higher than that of Cp-Ti and lower than that of Ti-6Al-4V.The coefficient of friction and wear increased with load.A tribological film was generated on the surface of the alloys in some cases.The film generation correlated with friction and wear by reducing and limiting the friction and wear.The tribological mechanism can be attributed to abrasive ploughing wear mechanisms.The precise tribological response was controlled by the microstructure, hardness, surface chemistry (tribofilm) in the wear track and load.Characterization of subsurface microstructures after tribology tests under different applied loads showed that grain refinement did occur adjacent to the rubbing surface.An increase in the extent of grain refinement was observed with an increase in load.For pure corrosion, alloys tend to form a passive film.The β-phase Ti-Ta30 had a relatively low corrosion current density because the more stable Ta2O5 passive films strengthen the TiO2 passive films.The corrosion potential under rubbing shifted cathodically and the current density increased compared with static corrosion.The current densities and mean corrosion rate increased after tribocorrosion tests, while the corrosion potential showed cathodic and anodic shifts, and this shifting V 1-3 Thesis outline Chapter 2, "Literature Review", and contains a brief introduction to biomaterials.Titanium and titanium alloys (microstructure, general properties, and motivation for design of βtitanium alloys as biomaterials) are also given in this chapter.A brief introduction to tribological, electrochemical and tribocorrosion phenomena is presented in this chapter.Chapter 3, "Experimental Procedure", contains the materials and methods used in this work.|This includes the detailed procedure used to prepare samples by Arc melting (materials and method, alloy fabrication, and arc melting process).Thermomechanical heat treatment and sample preparation is also explained in detail.The analysis of composition, microstructure and mechanical properties are also explained.Tribological, electrochemical and tribocorrosion tests are also presented.Chapter 4, "Results: Structural and Properties Characterization of Titanium and Titanium Alloys Fabricated in This Work", contains all the experimental results of composition analysis, transformation temperatures, phase analysis, microstructure analysis and mechanical properties of titanium alloys.Chapter 5, "Results: Tribological Behaviour of Titanium and Titanium Alloys Fabricated in This Work" contains all the experimental results of the tribological behaviour of the titanium alloys, and all characterization after tribological tests.Chapter 6, "Results: Electrochemical Behaviour of Titanium and Titanium Alloys Fabricated in This Work" contains all the experimental results of electrochemical behaviour of titanium alloys and all characterization after electrochemical tests.Chapter 7, "Results: Tribocorrosion Behaviour of Titanium and Titanium Alloys Fabricated in This Work", contains all experimental results of tribocorrosion behaviour, and all characterization after tribocorrosion tests.Chapter 8, the "Discussion", contains the discussion of experimental results for all work carried out on structural and properties characterization, tribological, electrochemical, and tribocorrosion behaviour of the alloys.Chapter 9, "Conclusions and Recommendations for future works" contains the main conclusions and new findings from the experimental of this work.Furthermore, the suggestion and recommendation for future work are also presented.
Author: Zuheir Talib Khulief
Institution: University of Sheffield
Language: English
Subfield: Materials Chemistry
Field: Materials Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2920915888
