Abstract: OBJECTIVES: This paper reports the development, validation, and public availability of a new neural network-based system which attempts to identify the manufacturer and even the model group of a pacemaker or defibrillator from a chest radiograph. BACKGROUND: Medical staff often need to determine the model of a pacemaker or defibrillator (cardiac rhythm device) quickly and accurately. Current approaches involve comparing a device's radiographic appearance with a manual flow chart. METHODS: In this study, radiographic images of 1,676 devices, comprising 45 models from 5 manufacturers were extracted. A convolutional neural network was developed to classify the images, using a training set of 1,451 images. The testing set contained an additional 225 images consisting of 5 examples of each model. The network's ability to identify the manufacturer of a device was compared with that of cardiologists, using a published flowchart. RESULTS: The neural network was 99.6% (95% confidence interval [CI]: 97.5% to 100.0%) accurate in identifying the manufacturer of a device from a radiograph and 96.4% (95% CI: 93.1% to 98.5%) accurate in identifying the model group. Among 5 cardiologists who used the flowchart, median identification of manufacturer accuracy was 72.0% (range 62.2% to 88.9%), and model group identification was not possible. The network's ability to identify the manufacturer of the devices was significantly superior to that of all the cardiologists (p < 0.0001 compared with the median human identification; p < 0.0001 compared with the best human identification). CONCLUSIONS: A neural network can accurately identify the manufacturer and even model group of a cardiac rhythm device from a radiograph and exceeds human performance. This system may speed up the diagnosis and treatment of patients with cardiac rhythm devices, and it is publicly accessible online.
Source: JACC. Clinical electrophysiology
Institutions: Imperial College London, University College London
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,330
Funders: Wellcome Trust, NIHR Biomedical Research Centre, Royal Marsden NHS Foundation Trust/Institute of Cancer Research, National Institute for Health and Care Research, British Heart Foundation, Imperial College London, Imperial College Healthcare NHS Trust, Rosetrees Trust, Medical Research Council, National Institute for Health Research Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, FP7 Ideas: European Research Council
Awards: Investigation of the physiological mechanisms through which Ventricular Tachycardia (VT) impairs cardiac function and exploration of potential clinical applicable therapy to improve cardiac output during VT (Dr Daniel Keene), G160493542, G1694711277, G2063655538, G2336095096, Applications of machine learning in clinical cardiovascular imaging, Rapid reliable volume status and ventricular function assessment by non-specialist staff using innovative imaging in clinical practice, The clinical significance of diffuse myocardial fibrosis in cardiomyopathy, Invasive haemodynamic evaluation of mechanisms and quantification of scope for innovation in biventricular pacing, The quantification of cardiac TTR amyloid: a diagnostic tool for better patient care, G6429968790, G6562015419, Experimental manipulation of indices of lesion severity in multi-vessel coronary artery disease: Quantitative exploration of collateral influences., G8094022638
OpenAlex ID: W2923923482