Abstract: PERFORMANCE OF FEEDBACK CONTROL LOGIC FOR AUTOMATED ADJUSTMENT OF WATER pH USED IN MICROIRRIGATION 2 ABSTRACT Clogging problems in emitters have been the major limitations for adoption of microirrigation systems, mainly drip irrigation. When clogging is caused by chemical agents, the treatment intended for pH adjustment constitutes a feasible solution, as it determines the conditions for ion precipitation, and therefore emitters clogging. The aim of this study was to evaluate the efficiency of three feedback control logic systems for automated adjustment of water pH in microirrigation systems. The following control logic was tuned and evaluated for water pH adjustment using a control system coupled with an acid injection device: proportional integral controller (PI), modified proportional integral derivative (MPID) , proportional integral derivative (PID). These control logic systems were efficient for adjusting water pH. Settling times of PID, PI and MPID controllers were 19.0, 20.0 and 68.5s, respectively. The Integral Time Absolute Error (ITAE) was 188.7 (PID), 239.4 (PI) and 3083.3 MPID, which shows that MPID controller had the highest instability for water pH control.