Work

On the use of a new possibilist importance measure to reduce Safety Integrity Level uncertainty

Year: 2006
Type: conference-paper
Abstract: Safety Instrumented Systems (SIS) play a key role in process industry to achieve safety. One of the most important criteria for SIS design is the requirement that the user assigns and verify Safety Integrity Level (SIL) of SIS. This paper proposes a new possibilist importance measure to reduce the SIL uncertainty when the SIS components failure probabilities are uncertain.
Source: HAL
Institution: CRAN
Language: English
Open Access status: green
OpenAlex ID: W29341848
FWCI: 3.968
Cites: 8
Cited by: 8