Work

Successful Qualification of the First PFM Space Dilution Refrigerator

Year: 2007
Type: article
Abstract: We report on the successful qualification down to 100 mK of the first space dilution refrigerator.This dilution refrigerator will cool down the bolomoters of the high frequency instrument (HFI) of the Planck Satellite for 18 months.For HFI, the required sensitivity ( T/T ~ 2.10-6) is achieved by using an array of bolometers cooled down to 100 mK by an open-cycle dilution cooler.To achieve the temperature of 100 mK, the isotopes are pre-cooled with external cryocoolers down to 4.5 K. Further cooling to less than 1.6 K is achieved through an internal Joule Thomson (J-T) expansion process on the mixture return line.The results obtained on the proto-flight model (PFM) at the J-T and dilution cooler stages are compared to those obtained with the qualification model.The influence of the pre-cooling temperature on the performance of the dilution cooler is also discussed.Potential applications of this cooler or of an upgraded version for other missions are presented.
Language: English
Open Access status: green
OpenAlex ID: W2941599263
FWCI:
Cites: 1
Cited by:
Related to: 10