Concentration-Gradient-Method for improvement of precision and accuracy of isotope ratio analysis using quadrupole based inductively coupled plasma-mass spectrometry

Year: 2018
Type: dissertation
Abstract: Isotope ratio analysis makes it possible to approach many analytical problems concerning the identity and provenance of different samples. In recent years the number of published applications on this topic increased greatly since introduction of stable isotope analysis by means of (Laser-Ablation) Multi-Collector-inductively-coupled-plasma mass spectrometer. However, the main disadvantage of these highly precise, so-called MC-ICP-MS, devices are very high investment costs. In this context, this thesis deals with the development of a novel approach to measure and evaluate more precise and accurate isotope ratios using commonly established and widespread quadrupole based ICP-MS (ICP-QMS) as it is possible by means of the common approach. The newly developed method is based on the constant isotope ratio at changed sample concentration. By means of an appropriate measurement setting, the linear relationship can be described by a suitable regression model by means of a mutual plot of signal intensities. As a result, this method requires a modification of the measurement procedure with respect to the classical method. Instead of measuring one well defined concentration, the measurement of a concentration series of the sample has to be performed. The resulting signal intensities of each isotope are plotted against each other in an x,y-diagram. The different concentrations of the samples correlate by a linear model. The slope of the estimated line is per definition the isotope ratio. Since both data sets are influenced by uncertainties the use of an orthogonal-distance-regression (ODR) model is required. This measurement and evaluation approach is called Concentration-Gradient-Method (CGM). One particularity of this kind of data evaluation is a significant increase of precision and accuracy of the isotope ratio determination performed with ICP-QMS. Moreover, a significant intercept is expressed by linear regression. It could be demonstrated that this intercept is a consequence of constant interference overlapping the isotope signals. Constant values that may cause such interference are signal noise and polyatomic interference of the measuring system as well as isobaric interference of the dilution medium. In the course of the optimization process, it was shown that transient measurements yield more precise results since the accuracy of the model depends on the incoming number of data points. For this reason, a program was written that greatly facilitated the very time-intensive analysis and thus allowed an enormous time-saving. The enhanced precision and accuracy by means of CGM could be demonstrated in comparative measurements using defined isotope standard-reference-solutions, which were measured under the condition of very poor signal-noise-ratios (S/N). A significant improvement of the accuracy could be achieved by means of CGM. In reproducibility test the newly developed CGM achieved a recovery rate of 103% independent of S/N, while the classical measurement approach showed a deterioration of the recovery rate up to 123%. In addition, only the use of CGM enabled plausible measurements of the sulphur isotope ratio even without using the collision/reaction cell of the ICP-QMS in gypsum samples of different origins. The massive interference of 16O2 on the signals of 32S were compensated by the intercept of the regression line, so that no further signal treatment was necessary. An further important application of isotope ratio analysis is the radiogenic Sr isotopic ratio determination for the identification of the origin of diverse food products to identify counterfeit products. However, this determination requires a complex sample preparation in the form of Rb separation by means of fractionated ion exchange chromatography to avoid isobaric interferences. Within the scope of this thesis, an alternative sample preparation procedure was developed based on the classical SrCO3 precipitation reaction. By this approach a two to five times better separation of Rb and Sr was achieved in mineral water and wine samples than in the standard approach. In combination with the CGM, mineral water and wine samples could be characterised by their Sr isotope ratio depending on their origin and varietal. The here developed cost-efficient and very effective sample preparation procedure increase the importance of isotope analysis by means of the widespread and in the routine analytic established ICP-QMS to a certain extant. Finally, a simple and effective modification of the CGM was developed using common Continuous-Flow-Analysis (CFA) techniques to allow a continuous change of a defined start concentration of a sample. The aim of this modification was a reduction of sample volume and maximisation of cost-efficiency due to minimisation of sample preparation steps, that also cause an avoidance of errors or contaminations by the reduction of pipetting steps. The continuous dilution method yielded three times more accurate results of the isotope ratio determination of different standard-reference-solutions with respect to previously described discontinuous CGM. The improvement was mainly caused by avoiding plasma disruption by air bubbles. Interference experiments additionally showed an influence on the precision, due to the decreased S/N, but the accuracy was still not affected (99.8 % WFR). In summary, the approach of continuous dilution is a simple and powerful modification of the here developed CGM.
Language: English
Field: Chemistry
Open Access status: green
OpenAlex ID: W2943674035
Cites:
Cited by:
Related to: 10