Wearable sensor monitoring in hospital care
Year: 2019
Type: dissertation
Abstract: Vital sign monitoring at the general wardMeasurements of vital signs such as heart rate, respiratory rate, blood pressure, temperature and oxygen saturation are common in hospitalized patients and provide insight in the patients' clinical condition.1 Nowadays, many vital signs can be measured (semi-)continuously with the possibility of remote monitoring.This is usual practice in high care environments such as the Intensive Care Unit (ICU), the Operating Theatre and the Emergency Department.In these care locations, care givers are immediately informed about deterioration of the patients' vital signs.At the general ward, however, vital signs are measured discontinuously and manually and are registered by nurses on average three times in 24 hours, which basically means one time every work-shift.As a result, vital signs are 'monitored' via the electronic health record (EHR). Early warning scoresClinical deterioration regularly occurs in hospitalized patients, which may lead to life threatening events or death.2,3 To assist care givers in the early identification of deteriorating patients at the general ward, scores have been developed based on vital signs.These scores are called Early Warning Scores (EWS) and were first reported in 1997 by Morgan and associates.4 The Modified Early Warning Score (MEWS) is an example of an EWS and is commonly used.5-7 A higher MEWS is associated with a worse clinical condition of the patient and an increased number of ICU admissions and cardiac arrests.8-10 A recent review shows that the predictive value of EWS is high and that use of EWS benefits patient outcome.11 However, significant limitations of EWS are also reported.Vital signs underlying the scores are not regularly measured, documented or interpreted at the general ward, sometimes due to unfamiliarity with the locally used EWS system.[12][13][14][15][16] Also, routine measurement of vital signs is subjected to inaccuracy and incompleteness.3,17,18 For example, respiratory rate, an important predictor of sepsis and mortality, 19,20 is often incorrectly measured and underestimated by nurses.21 Furthermore, many nurses consider the measurements as time-consuming.21 The intermittent and manual measurements of vital signs at the ward harbor serious safety risks.22 Patients may deteriorate in between measurements which is unnoticed by nurses.This is particularly the case during night hours when they are less attended by nurses.23 A delayed detection of deterioration leads to unplanned ICU admissions, which are associated with higher mortality ranging between 20% and 65%, a longer hospital stay, [24][25][26] and a 60% increase of hospitalization costs.27 More frequent measurements such as intensified periodic and continuous monitoring may result in earlier detection of significant changes in vital signs, that can predict life threatening events.28 This is why patients at high risk of deterioration are often admitted to higher care units with continuous monitoring of vital signs at admission or immediately after surgery.29 Chapter 1 14 Increase in vulnerable groups for deterioration at wardsThe median age of hospitalized patients increases due to an ageing population and more elderly patients are eligible for complex medical and surgical treatments.30 Particularly the frail older patients may deteriorate more often, suffer from more complications and increased mortality associated with hospital admissions.31 There is an increasing desire to monitor these patients more intensively regarding vital signs at the general ward, also because of limited high care capacity.32, 33 Continuous monitoring and predictionIntensified periodic or continuous monitoring at the general ward may be useful to detect changes in patients' vital signs earlier in comparison with discontinuous assessment of an EWS.Combined with predictive analytics, early detection followed by early activation of a rapid response team (RRT) and early intervention 34 potentially leads to improved survival and a decrease in hospital length of stay.35 There are more possible advantages of continuous and remote monitoring at the general ward.Nurses do not have to enter patients' room for vital sign measurements, which reduces workload.Less disturbances improves patient's comfort and sleep at night, and ultimately can enhance recovery.[36][37][38] Data transmission from the continuous monitoring device to the EHR can be automated, reducing human errors of reporting.Patients can have better insight in their own medical data, which supports patient participation and self-management in hospital care.39 Wearable devices for continuous monitoringIn contrast with high care units where most patients are monitored lying in bed, continuous monitoring of vital signs at the general ward should facilitate patient mobilization.In comparison with patients in high and medium care units, patients at the ward more often change posture in bed, sit in a chair or walk in or outside their room.These posture changes and mobilization demand specific requirements of the monitoring devices.Furthermore, devices have to transmit data wirelessly, contain non-invasive and unobtrusive sensors and preferably can be worn on clothes or placed directly on the skin of an easily accessible part of the body.40 Most wearable devices are initially developed by the life style industry for fitness and wellness and include smart watches, patches or tattoos.[41][42][43] Some devices are potentially suitable to be used in medical practice, particularly those that measure heart rate, respiratory rate, oxygen saturation, blood pressure and temperature.43 However, devices have to meet several demands for safe and effective introduction in healthcare and have to be approved by regulatory authorities for medical devices.Devices have to be reliable and accurate in measuring vital signs in a broad range of normal and abnormal values.Important is the property to set individual thresholds of vital signs or scores for alarming.40 Many investigators have already claimed reliability and accuracy, however, these are proven in healthy volunteers with a normal range of values.Furthermore, unbiased reporting is questionable since researchers are often involved in the 2001;
Author: Mariska Weenk
Institution: Radboud University Nijmegen
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2945361921
