Work

Short-Term Stability of Hematologic Parameters in Frozen Whole Blood

Year: 2019
Type: article
Abstract: BACKGROUND: Complete blood counts (CBCs) are commonly obtained in large multicenter studies. We assessed the stability of 10 parameters after short-term (up to 30 days) frozen storage. METHODS: We compared CBC measurements from fresh samples (n = 53) with samples stored for up to 30 days at -70 °C. We calculated the CVs and intraclass correlation coefficients. RESULTS: Mean values of most parameters, with the exception of hemoglobin and platelet count, were significantly different by 15 days of storage. White blood cell count (CV, 38.3%; 95% CI, 31.3%-46.2%) and red cell distribution width (CV, 37.7%; 95% CI, 34.1%-41.3%) were the most variable. After 30 days, only hemoglobin remained stable and reliable (CV, 0.8%; 95% CI, 0.4%-1.3%). CONCLUSIONS: Hemoglobin remained stable in frozen blood samples stored for up to 30 days at -70 °C and may be reliably used in research studies using short-term frozen specimens. Other CBC parameters measured in stored blood are not sufficiently reliable for research or patient care.
Language: English
Subfield: Physiology
Field: Medicine
Open Access status: bronze
OpenAlex ID: W2962738667
FWCI: 0.686
Cites: 15
Cited by: 9