Prospective comparison of two excimer laserplatforms in treatment of high astigmatism withlaser in situ keratomileusis [Prospektivna usporedba dvije laserske platforme u tretiranju visokog astigmatizma laser in situkeratomijeluzom]

Year: 2019
Type: dissertation
Abstract: PURPOSE: Comparison of Wavelight Allegretto Eye-Q and Schwind Amaris 750S excimer laser groups after performed LASIK procedure regarding functional parameters – uncorrected (UDVA) and corrected distant visual acuity (CDVA), residual refractive error, astigmatism outcomes by means of vector analysis and high order aberrations in patients with high astigmatism (more than 2 diopters (D)). ----- METHODS: 135 patients with myopic astigmatism (246 eyes) and 102 patients with mixed astigmatism (172 eyes) underwent LASIK correction (some of the patients had only one eye operated – the eye that met the criteria for the study, while the other eye had no diopter at all) and were divided in 4 groups: 1 – myopic astigmatism corrected with Allegretto, 2 – myopic astigmatism corrected with Amaris, 3 – mixed astigmatism corrected with Allegretto and 4 – mixed astigmatism corrected with Amaris. Data were analysed to determine significance of change in spherical correction, astigmatism, UDVA, CDVA, high order aberrations, and also vector analysis by Thibos (J0 and J45) and Alpins method was performed. ----- RESULTS: Visual acuity improvement for group 1 was statistically significant (p=0.017); for group 2, 3 and 4 was not statistically significant (p=0.06, p=0.406, p=0.115). None of the eyes lost any lines of CDVA. Regarding refractive results, for all groups there was almost complete elimination of spherical and cylindrical refractive error. High-order aberrations results for groups 1 and 2 showed no significant change between preoperative and postoperative high-order aberrations, while in groups 3 and 4 spherical aberrations changed. Vector analysis by Thibos showed statistically significant difference between J0 preop and J0 postop for both platforms (p<0.001). There was statistically significant difference for J45 postoperatively between the platforms (p=0.012). Correlation between ΔJ0 and preop J0 values (groups 1 and 2) showed that the difference between these two correlation coefficients was significant (z=−3.086, p=0.002). There was statistically significant difference in preoperative mean values for J0 (p<0.001) between the groups 3 and 4. There was a statistically significant difference between J0 preop and J0 postop for both platforms (p<0.001). Correlation between ΔJ0 and preop J0, and between ΔJ45 and preop J45 for groups 3 and 4 showed that difference between these two correlation coefficients was significant (z=−3.533, p=0.0004; z=−2.886, p=0.004). Vector analysis by Alpins showed that negative SIA power (y1) was significantly correlated with negative TIA power (x1) and sine of the TIA axis (x2) as follows: [a] i, y1=0.829X1–0.403X2–0.325 (F=87.76, R=0.804, P<0.001, N=127); ii, y1=0.891X1–0.037X2-0.192 (F=240.06, R=0.901, P<0.001, N=119) and [b] i, y1=1.063X1+0.233X2+0.411 (F=990.99, R=0.881, P<0.001, N=61); ii, y1=1.029X1– 0.115X2+0.322 (F=270.12, R=0.908, P<0.001, N=111). The sine of negative SIA axis (y2) was significantly correlated with negative TIA power (x1) and TIA axis (x2) as follows: [A] I, y2=0.951x2–0.007x1+0.008 (F=446.58, r=0.950, p<0.001, n=127); II, y2=0.856x2+0.007x 1+0.105 (F=277.18, r=0.912, p<0.001, n=119) and [B] I, y2=0.953x2 +0.009x1+0.075 (F=362.6, r=0.963, p<0.001, n=61); II, y2=0.977x2–0.004x1+0.002 (F=2910.9, r=0.990, p<0.001, n=111). ----- CONCLUSIONS: Both lasers showed effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction. There was no genuine difference post-operatively between groups treated on two different laser platforms according to the vector analyses by Thibos. By using Alpins method, we revealed that both platforms were similar in tending to undercorrect astigmatism; axis rotational errors were apparent, although overall the two platforms differed in terms of direction; and the predicted angle between the SIA and TIA tended to increase when the astigmatic correction was against-the-rule.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: green
OpenAlex ID: W2965115684
Cites: 88
Cited by:
Related to: 8