Work

Ex vivo electrochemical measurement of glutamate release during spinal cord injury

Year: 2019
Type: article
Abstract: Excessive glutamate release following traumatic spinal cord injury (SCI) has been associated with exacerbating the extent of SCI. However, the mechanism behind sustained high levels of extracellular glutamate is unclear. Spinal cord segments mounted in a sucrose double gap recording chamber are an established model for traumatic spinal cord injury. We have developed a method to record, with micro-scale printed glutamate biosensors, glutamate release from ex vivo rat spinal cord segments following injury. This protocol would work equally well for similar glutamate biosensors.
Source: MethodsX
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $600
OpenAlex ID: W2969476092
FWCI: 0.157
Cites: 12
Cited by: 2
Related to: 10