Work

XCO 2 observations using satellite measurements with moderate spectral resolution: investigation using GOSAT and OCO-2 measurements

Year: 2020
Type: article
Abstract: . In light of the proposed space segment of Europe's future CO2 monitoring system, we investigate the spectral resolution of the CO2 spectrometer, which measures Earthshine radiance in the three relevant spectral bands at 0.76, 1.61 and 2.06 μm. The Orbiting Carbon Observatory-2 (OCO-2) mission covers these bands with fine spectral resolution but limited spatial coverage, which hampers the monitoring of localized anthropogenic CO2 emission. The future European CO2 monitoring constellation, currently undergoing feasibility studies at the European Space Agency (ESA), is targeting a moderate spectral resolution of 0.1, 0.3 and 0.3–0.55 nm in the three spectral bands with high signal-to-noise (SNR) ratio. This spectral and radiometric sizing is deemed to be favorable for large-swath imaging of point-sources of CO2 emission. To assess this choice, we use real and synthetic OCO-2 satellite observations, which we spectrally degrade to the envisaged lower spectral resolution. We evaluate the corresponding CO2 retrieval accuracy by taking the Total Carbon Column Observing Network (TCCON) observations as reference. Here, a lower spectral resolution enhances the scatter error of the retrieved CO2 column mixing ratio (XCO2) but has little effect on the station-to-station variation of the biases. We show that the scatter error gradually increases when decreasing spectral resolution. Part of the scatter error increase can be attributed to the retrieval noise error which can be compensated by a future instrument with improved SNR. Moreover, we consider the effect of the reduced spectral resolution on the capability to capture regional XCO2 variations and XCO2 plumes from selected OCO-2 orbits. The investigation using measurements from the Greenhouse gases Observing SATellite (GOSAT) and synthetic measurements confirms our finding and indicates that one major source of uncertainties regarding CO2 retrieval is the insufficient information on aerosol properties that can be inferred from the observations. We hence recommend the implementation of simultaneous, co-located measurements that have larger information content on aerosols with an auxiliary instrument in the future European observing system.
Language: English
Open Access status: gold
Estimated APC paid: $1,585
Award: G458420017
OpenAlex ID: W2969732604
FWCI: 1.008
Cites: 58
Cited by: 21
Related to: 10