Stent-based endovascular brain interface: characterization of recording and stimulating properties
Year: 2019
Type: dissertation
Abstract: Brain interfaces have the potential to treat traumatic and degenerative neurological conditions, which are major causes of morbidity and disability in modern society.However, despite outstanding progress and numerous promising research outcomes, very few brain interfaces reach a compromise between safety and performance needed to provide a chronic benefit for the patient.The Stentrode is the first ever stent-mounted, multielectrode and chronic brain interface that provides intracranial access to brain activity through the vasculature, with no need for burr-holes or brain penetration.It holds promise for increased safety during and after deployment, while remaining in proximity to neurons.This thesis aimed to investigate the performance of this novel device, the Stentrode, and provide empirical evidence on its ability to reliably access and deliver information to the brain.Firstly, we analysed chronic, endovascular signal quality.Full-field flashes were delivered in awake sheep and recorded with Stentrodes implanted in a dural vessel (superior sagittal sinus).Signal amplitude measures and impedance spectra were collected in the first 30-days post-stent deployment daily in the first two weeks and at alternate days thereafter.Results indicated stabilisation in the third week; however, large, repeatable and cortically widespread visual evoked responses remained significantly larger than background activity throughout the duration of the experiment, suggestions an overall minimal impact on immune response on recording quality.Next, we focussed on feasibility and efficacy of endovascular brain stimulation.The delivery of electrical pulses from within the vasculature has entered clinical practice in the peripheral nervous system however, surprisingly, systematic experimental results on intracranial endovascular stimulation are lacking.We delivered electrical stimuli using chronically implanted Stentrodes, while monitoring brain activation using a large subdural grid in anesthetised sheep.We observed a monotonic growth function for the response amplitude versus stimulation current and identified the current thresholds to vii Declaration of Authorship I hereby declare that this thesis and the work presented in it are original and generated by me as the results of my own investigations.In the research described in the thesis, I undertook the majority of the work and have made the leading contribution.For the most part I fabricated the Stentrodes, tested every implanted device prior implantation and developed the experimental paradigms.Except where acknowledged below, I was responsible for data collection, data analysis, software programming, and generation of images, writing and graphical data.
Author: Giulia Gerboni
Institution: The University of Melbourne
Language: English
Subfield: Cellular and Molecular Neuroscience
Field: Neuroscience
Domain: Life Sciences
Open Access status: green
OpenAlex ID: W2969925913