Work

Pharmacokinetics and Dialytic Clearance of Isavuconazole during In Vitro and In Vivo Continuous Renal Replacement Therapy

Year: 2019
Type: article
Abstract: 4.85±3.79 L/h, and AUC 54.01±20.98 mg ⋅ h/L. Transmembrane clearance represented just 0.7% of the total isavuconazole clearance. These data suggest that isavuconazole is not readily removed by CRRT and no dose adjustments are necessary.
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2973610239
FWCI: 1.342
Cites: 26
Cited by: 18
Related to: 10