Year: 2017
Type: dissertation
Abstract: To conserve energy and promote environmental sustainability, the power industry has invested a great \ndeal into the generation of electricity using renewable energy (RE) sources. For such applications, high \nvoltage direct current (HVDC) systems are considered a highly efficient alternative for bulk power \ntransmission. Recent advances in technology favour the use of voltage source converter (VSC) based \nHVDC systems for the integration of RE sources. These schemes are favoured for their controllability and \nprovide major reinforcements to the power systems. Despite its promising future, the technology is \nconstrained by the unavailability of a reliable protection scheme, as the operating times for HVDC \nprotection schemes are required to be ten to a hundred times faster than existing AC protection \nalgorithms. \nVSC-HVDC networks are usually more vulnerable to DC-side faults. Selective protection against these \nfaults is therefore essential for safe and reliable operation of the network. This study provides the \nnecessary concepts to develop VSC-HVDC protection algorithms for multi-terminal (MT) meshed HVDC \nsystems. DC fault characteristics were initially investigated. They provided a basic understanding of the \nVSCs natural responses to DC fault scenarios. The study also focused on analysing factors that may \nadversely influence the systems protection performance. These include the DC fault distance, DC-link \nconductor sizes and DC fault impedance. Results obtained from these variations show that the DC-link \ncapacitor was one of the main sources that cause the high rise of DC fault currents and that these are the \nhighest and the most dangerous when closest to the converter station. \nWith a clear understanding of the DC fault characteristics, a protection scheme has been proposed. \nInitially, different methods are discussed with the intent of deciding on the scheme that is the most \nsuitable. Detection techniques based on the discrete wavelet transform (DWT) for primary protection and \nthe current derivative technique for back-up were chosen as the most promising. These techniques offer \naccuracy, speed and selectivity which are factors that are all important for the network. The single VSC \nterminal travelling wave technique was implemented to identify the exact position of a DC fault. This \nmethod reduces costs as it eliminates the need of communication links. Finally, to isolate the affected \ncables, the hybrid DC circuit breakers (CB) were implemented into the VSC-HVDC system. The CBs \nhave been coupled with a reactance for fault current limiting and to isolate the system before it reaches an \nuninterruptable current magnitude. Back-up AC CBs were included on the AC side of the network and \nwere stationed to separate the VSC network from the AC grid in cases where the implemented primary \nprotection scheme fails.
Author: Mbalenhle Nokwanda. Chamane
Institution: University of KwaZulu-Natal
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2989888877