Abstract: The critical velocity and backlayering length in sloped tunnels are investigated by numerical simulations using FDS. Simulation in two full-scale tunnels, with negative slopes ranging up to -18 % and heat release rates from 5 to 100 MW were carried out. The results show that NFPA 502 equation significantly overestimates the effect of negative slopes. The equation proposed by Atkinson and Wu is found to be in closer agreement with the results. A simplified correlation, i.e. Eq. (12), is proposed and recommended for practical use. The previous correlation for dimensionless backlayering length, Eq. (3), is valid for tunnels of various slopes and aspect ratios, and can be used for prediction of backlayering length.