An integrated assessment of nanoparticle exposures in the ceramic industry

Year: 2019
Type: dissertation
Abstract: Exposure to nanoparticles has been associated with adverse effects on human health. When the exposure route is inhalation, nanoparticles can cause pulmonary inflammation which may be more severe than from fine particles, while significant associations between nanoparticles and cardiovascular morbidity have also been also observed. Consequently, industrial processes which release airborne nanoparticles into workplace air have become an issue of growing concern with regard to occupational exposure and potential health hazards for workers. Nanoparticles emitted by industrial activities may be engineered and used as input/output in a process, or formed unintentionally as a result of a given industrial activity and are referred to as process-generated nanoparticles. The latter have high probability to be released from high energy processes (e.g. thermal) and to impact exposure in various scenarios at diverse industrial settings.\n\t\t\t\t The present PhD Thesis has three main objectives: to identify nanoparticle sources in industrial settings and characterize their release mechanisms, to characterize the different exposure scenarios, and to assess the effectiveness of mitigation strategies for exposure reduction. These objectives were addressed by applying an integrated assessment of nanoparticle exposures in real-world scenarios. All of the industrial scenarios studied were related to the ceramic industry (e.g. laser ablation of ceramic tiles, thermal spraying of ceramic coatings). The results obtained are presented in the form of four scientific papers.\n\t\t\t\t The first scientific publication (1) identified pulsed laser ablation of ceramic tiles as a source of process-generated nanoparticles. This work studied the mechanisms controlling nanoparticle formation and release during ablation of different types of ceramic tiles. High particle number concentrations were detected (3.5×104 to 2.5×106 cm-3) for all of the tiles and with both lasers assessed (near- and mid-infrared). Different particle release mechanisms were identified: during ablation with the near-IR laser particles were emitted through melting and nucleation, while emissions from the mid-IR laser were attributed to melting and mechanical shockwaves. Particle number and mass emissions were dependent on the tile surface characteristics as well as the laser parameters.\n\t\t\t\t The second publication (2) characterized nanoparticle emissions and their impact on exposure during thermal spraying of ceramic coatings in a real-world industrial scenario. High particle number (>106 cm−3; 30–40 nm) and mass (60–600 μgPM1 m−3) concentrations were recorded inside the spraying booths, which impacted exposure in the worker area (104–105 cm−3, 40–65 nm; 44–87 μgPM1 m−3). Irregularly-shaped, metal-containing particles (Ni, Cr, W) were sampled from the worker\n\t\t\t\t \n\t\t\t\t area and a direct link between the spraying activity and exposure was established. In terms of particle number count, 90% of the particles were nanoparticles with sizes 26–90 nm. The third publication\n\t\t\t\t (3) discussed the hygroscopic properties of these nanoparticles, which were monitored online with an HTDMA. The nanoparticles emitted were found to take up moderate amounts of water when exposed to elevated relative humidity (87% RH), with their hygroscopicity being distinguishably lower compared to that of the atmospheric background aerosol particles present in the workplace air. Thus, particle hygroscopicity was identified as a useful metric to discriminate process-generated from background particles in workplace air.\n\t\t\t\t Finally, the fourth scientific publication (4) quantified the effectiveness of mitigation strategies implemented during four different exposure scenarios under real-world settings. The nanoparticle removal efficiency of source enclosure combined with local exhaust ventilation was quantified to range between 65-99%, The highest efficiency was achieved by the combined use of a strong local exhaust ventilation with full enclosure (99.8%), tested during thermal spraying. Source substitution achieved a 91.5% reduction of exposure concentrations in the worker breathing zone, lower than the expected 100% due to interference from simultaneous sources. Mask respirators managed to reduce worker exposure by 86.7%, whereas source isolation reached maximum efficiency of 84.4%. The results highlight the interdependence of different mitigation strategies (e.g., LEV and source enclosure), which are frequently implemented simultaneously in real-world industrial scenarios. The mitigation measures for exposure reduction have proven to be more efficient when tailored to each specific industrial scenario.\n\t\t\t\t The combination of key information and analyses deriving from the experimental scenarios assessed allowed to extract conclusions and recommendations with direct application to the industrial sector under study.
Language: English
Open Access status: green
OpenAlex ID: W2992932754
Cites: 280
Cited by:
Related to: 10