Bir Binanın Değişken Cam ve Dış Duvar Tiplerine Göre Pencere/Duvar Alanı Oranlarının Bina Isı Kayıplarına Etkisi
Year: 2017
Type: article
Abstract: The opaque and transparent surfaces of buildings have an important role in terms of energy loss and gains. In buildings, the amount of heat loss from the windows depends on window/ wall area ratio, glass type and frame. In this study, discrete residential building located in the province of Antalya with hot-humid climatic conditions has been examined. Effect of change of window/wall area ratio in different directions on heat loss for different glass type is calculated using the mechanical installation calculations program. According to the results obtained, window/ wall area ratio (% 30, % 40) and glass type (double glazing, single glazing and coating glazing/low-e) has been found to be effective on energy consumption.The heat loss calculations were repeated using double glazing instead of single glazing and coated reflective glazing to minimize this increase. Within the results, it is aimed to find optimum value in terms of applicability and economy. These parameters which are also influential on the energy performance of the building, are thought to contribute to the architectural design phase or the energy improvements of existing buildings.
Source: Mühendis ve Makina
Authors: Tansel Koyun, Ersin Koç
Institution: Süleyman Demirel Üniversitesi
Language: Turkish
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W3014882467