Year: 2018
Type: article
Abstract: This paper presents a novel method for QRS detection. To accomplish this task ECG signal was first filtered by using a third order Savitzky Golay filter. The filtered ECG signal was then preprocessed by a Wavelet based denoising in a real-time fashion to minimize the undefined noise level. R-peak was then detected from denoised signal after wavelet denoising. Windowing mechanism was also applied for finding any missing R-peaks. All the 48 records have been used to test the proposed method. During this testing, 99.97% sensitivity and 99.99% positive predictivity is obtained for QRS complex detection.
Institutions: Integral University, Aligarh Muslim University
Language: English
Topic: ECG Monitoring and Analysis
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
Funder: Aligarh Muslim University
OpenAlex ID: W3019008244