Quantified Design Guidelines of Compact Active EMI Filters to Reduce the Common-Mode Conducted Emissions
Year: 2018
Type: dissertation
Abstract: In switching mode power supplies (SMPS), noise currents induced by the switching operation travel along the input power line and may, in turn, cause interference with other electronic systems, including the SMPS???s auxiliary circuit. The noise current, caused by the switching operation to convert the voltage, is the main source of the conducted emissions. \nThe passive EMI filters (PEFs) composed of a common mode (CM) chokes, Y-capacitors, and X-capacitor are generally used to suppress the conducted emissions. However, the CM chokes are bulky and occupy a lot of room. Y-capacitors cause the undesired touch current flowing from the power lines to the earth GND. \nIn this thesis, three types of active EMI filters (AEF) ??? 1) voltage-sense voltage compensation (VSVC); 2) voltage-sense current-compensation (VSCC); 3) current-sense current-compensation (CSCC) ??? have been proposed to help overcome the limitation of the PEFs. The proposed AEFs have been designed as the feed-forward or transformerless configurations to manufacture in the compact size. Each AEF is completely analyzed by using the equivalent circuit model. Based on the rigorous analysis, the design guidelines of each AEF are established. In the design guidelines, the practical issues regarding the stability and high-voltage immunity are also considered. The performance of each AEF is validated through the experiments using a vector network analyzer (VNA) and the CM-conducted emissions measurements. \nThe feed-forward VSVC AEF is designed in a compact package to suppress CM-conducted emissions. The power line impedance is enlarged by the VSVC AEF and verified through the measurement. The VSVC AEF was installed in a 200W switching mode power supply (SMPS) board with 64 kHz and 110 kHz switching frequencies, demonstrating its usefulness by experiments. The performance degradation due to the magnetic saturation and the AEF grounding impedance was also analyzed and investigated \nThe transformerless VSCC AEF is developed to avoid the degradation due to the magnetic saturation. The sensing and compensation part is realized by only the capacitors, and the push???pull amplifier is utilized to generate the compensation signal corresponding to the sensed noise. Furthermore, the protection circuits against the high-voltage transient are developed and applied into the AEF. The VSCC AEF is then implemented into a real 2.2 kW current resonant inverter, and the conducted emissions are reduced by 5dB to 25 dB at a frequency range from 150 kHz to 6 MHz. In addition, the AEF???s immunity against high-voltage transients is demonstrated by lightning surge tests. \nThe CSCC AEF is designed as the symmetric structure using the capacitive coupling. The transformer with a small number of turns is utilized for the sensing transformer to avoid degradation due to the magnetic saturation. The CSCC AEF is also designed using the proposed design guidelines and employed into the real product. In the CM conducted emissions measurement, the CSCC AEF shows 5~20 dB noise attenuation from 150 kHz to 10 MHz. The degradation of the CSCC AEF due to the asymmetric structure is investigated by using the VNA measurements.
Author: Dongil Shin
Institution: Ulsan National Institute of Science and Technology
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W3036791502