Work

Simplified Quantification of 11C-UCB-J PET Evaluated in a Large Human Cohort

Year: 2020
Type: article
Abstract: 11C-UCB-J ((R)-1-((3-(11C-methyl-11C)pyridin-4-yl)methyl)-4-(3,4,5-trifluorophenyl)pyrrolidin-2-one) is a PET tracer for synaptic vesicle glycoprotein 2A, which may be a marker of synaptic density. To simplify the scan protocol, SUV ratios (SUVRs) were compared with model-based nondisplaceable binding potential (BPND) to select the optimal time window in healthy and neuropsychiatric subjects. Methods: In total, 141 scans were acquired for 90 min. Arterial blood sampling and metabolite analysis were conducted. SUVR-1 (centrum semiovale reference region) was computed for six 30-min windows and compared with 1-tissue-compartment model BPND. Simulations were performed to assess the time dependency of SUVR-1. Results: Greater correlation and less bias were observed for SUVR-1 at later time windows for all subjects. Simulations showed that the agreement between SUVR-1 and BPND is time-dependent. Conclusion: The 60- to 90-min period provided the best match between SUVR-1 and BPND (−1% ± 7%); thus, a short scan is sufficient for accurate quantification of 11C-UCB-J–specific binding.
Institution: Yale University
Language: English
Field: Medicine
Open Access status: bronze
OpenAlex ID: W3041366959
FWCI: 1.904
Cites: 12
Cited by: 28
Related to: 10