Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver
Year: 2020
Type: article
Abstract: Purpose To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton‐density fat fraction (PDFF), , and T 1 . These parameters are established biomarkers of hepatic steatosis, iron overload, and fibrosis/inflammation, respectively, which can occur simultaneously in the liver. Methods Phantoms including multiple vials were constructed. Peanut oil was used to modulate PDFF, MnCl 2 and iron microspheres were used to modulate , and NiCl 2 was used to modulate the T 1 of water (T 1,water ). Phantoms were evaluated at both 1.5 T and 3 T using stimulated‐echo acquisition‐mode MRS and chemical shift–encoded MRI. Stimulated‐echo acquisition‐mode MRS data were processed to estimate T 1,water , T 1,fat , , and for each vial. Chemical shift–encoded MRI data were processed to generate PDFF and maps, and measurements were obtained in each vial. Measurements were evaluated using linear regression and Bland‐Altman analysis. Results High‐quality PDFF and maps were obtained with homogeneous values throughout each vial. High correlation was observed between imaging PDFF with target PDFF (slope = 0.94‐0.97, R 2 = 0.994‐0.997) and imaging with target (slope = 0.84‐0.88, R 2 = 0.935‐0.943) at both 1.5 T and 3 T. The values of and were highly correlated with slope close to 1.0 at both 1.5 T (slope = 0.90, R 2 = 0.988) and 3 T (slope = 0.99, R 2 = 0.959), similar to the behavior observed in vivo. The value of T 1,water (500‐1200 ms) was controlled with varying NiCl 2 concentration, while T 1,fat (300 ms) was independent of NiCl 2 concentration. Conclusion Novel quantitative MRI phantoms that mimic the simultaneous presence of fat, iron, and fibrosis in the liver were successfully developed and validated.
Source: Magnetic Resonance in Medicine
DOI: 10.1002/mrm.28452
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
Awards: Technical Validation of MR Biomarkers of Obesity-Associated NAFLD, Quantitative Magnetic Resonance Imaging Phantoms, MRI-based Quantitative Susceptibility Mapping of Hepatic Iron Overload, Confounder-Corrected Quantitative MRI Biomarkers of Hepatic, Quantitative Magnetic Resonance Imaging Phantoms, Evolution of Quantitative MRI Biomarkers of Metabolic Syndrome During Puberty, Technical Development of Quantitative Biomarkers of Fatty Liver Disease with MRI
OpenAlex ID: W3048705637
