Work

Development of ocular implants using a supercritical fluid foaming/ mixing methodology

Year: 2017
Type: dissertation
Abstract: Despite advances in ophthalmological pharmacology, the treatment of eye diseases have limitations since conventional methods of drug delivery are not completely effective. A possible solution for the maintenance of therapeutic levels within the eye includes the controlled release systems such as implants, capsules, liposomes and iontophoresis. Supercritical carbon dioxide (scCO2) foaming/mixing methodology (SFM) is an alternative processing method that has unique advantages over standard techniques, including porosity control, absence of organic solvents and reduction of the melting (Tm) and glass transition temperatures (Tg) which is an important condition in what concern the incorporation of thermally and chemically sensitive drugs. In this type of processing, the polymer phase melts due to the dissolution of the fluid phase, and pores are formed upon fluid release. Thus, the main propose of this work was the development of poly (ε-caprolactone) (PCL) ocular implants loaded with drugs of ophthalmological interest (dexamethasone (DXMT), used to prove the concept and due to its lower price and frequent use in the treatment of ophthalmological disorders, and 2-Chloro-N6-(3-iodobenzyl)-adenosine-5'-N-methyluronamide (2-Cl-IB-MECA), a promising drug for future in vivo application) using SFM process. To achieve viable implant dimensions and to evaluate the effect of material porosity in drug release were also defined objectives. Pure PCL, PCL with glycofurol and PCL with glycofurol and the selected drugs were processed by scCO2 at 45 ° C, 200 bar, for two hours. Depressurization rates tested were 10, 20 and 30 bar/min. Produced implants have similar dimensions to ophthalmologic implants currently marketed (length 2 mm and diameter ≤ 0.464 mm). Glycofurol was shown to be important to ensure compatibilization of the polymer/drug mixture because, when used, there was greater drug incorporation. The ideal percentage of glycofurol determinate was 8% (w/w). SEM images show that all samples have a heterogeneous pore distribution influenced by depressurization rate and glycofurol presence: higher depressurization rate produces smaller pores and additive presence generates larger pores at the same depressurization rate. Largest pores obtained were for SFM10. There is a small difference in pore size between SFM20 and SFM30 which suggests that, on a small scale, like the ocular implants one, this variation in the depressurization rate may not be relevant. At same depressurization rate, additive presence generates larger pores. DSC analysis shows that PCL thermal properties were not significantly altered after processing. Dexamethasone implants revealed controlled release for more than 500 hours. Comparing DXMT implants produced by hot melting and processed with supercritical carbon dioxide, it is observed that until 200h of release, SFM implants release is more stable and higher than HM implants. After that time, HM appears to become stable but still lower. This is due to higher porosity in SFM implants. Implants produced by hot melting have smaller surface area and less porosity. Despite a similar release trend, due to porosity effect, 2-Cl-IB-MECA SFM20-G implants have higher drug release than 2-Cl-IB-MECA SFM30-G. 2-Cl-IB-MECA implants showed sustained release over 100 h. Release is greater in the first 60% of release profile and faster without additive addition due to less polymer-drug compatibilization. The amount of drug released in the first hour was eight times higher than the required on an intravitreal injection. Preliminary in vivo tests with PCL implants drug free didn’t reveal adverse side effects.
Language: English
Open Access status: green
OpenAlex ID: W3095401137
Cites: 90
Cited by:
Related to: 10