High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry
Year: 2017
Type: article
Abstract: An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer Mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S1/2 F = 4 133Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated with one-sigma tolerances in magnitude, orientation, and gradient of δ|B| = 0.94 nT, δθ = 5.9 mrad, and δ|∇B|=13.0 pT/mm, respectively. This field control is used to empirically map Mx magnetometer signal amplitude as a function of the static field (B0) orientation.
Source: Review of Scientific Instruments
DOI: 10.1063/1.4980159
Authors: S. J. Ingleby, P. F. Griffin, A. S. Arnold, M. Chouliara, E. Riis
Institution: University of Strathclyde
Language: English
Subfield: Atomic and Molecular Physics, and Optics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2604892846