Diffusion‐PEPTIDE: Distortion‐ and blurring‐free diffusion imaging with self‐navigated motion‐correction and relaxometry capabilities
Year: 2020
Type: article
Abstract: Purpose To implement the time‐resolved relaxometry PEPTIDE technique into a diffusion acquisition to provide self‐navigated, distortion‐ and blurring‐free diffusion imaging that is robust to motion, while simultaneously providing T2 and mapping. Theory and Methods The PEPTIDE readout was implemented into a spin‐echo diffusion acquisition, enabling reconstruction of a time‐series of T2‐ and ‐weighted images, free from conventional echo planar imaging (EPI) distortion and blurring, for each diffusion‐encoding. Robustness of PEPTIDE to motion and shot‐to‐shot phase variation was examined through a deliberate motion‐corrupted diffusion experiment. Two diffusion‐relaxometry in vivo brain protocols were also examined: (1)1 × 1 × 3 mm3 across 32 diffusion directions in 20 min, (2)1.5 × 1.5 × 3.0 mm3 across 6 diffusion‐weighted images in 3.4 min. T2, , and diffusion parameter maps were calculated from these data. As initial exploration of the rich diffusion‐relaxometry data content for use in multi‐compartment modeling, PEPTIDE data were acquired of a gadolinium‐doped asparagus phantom. These datasets contained two compartments with different relaxation parameters and different diffusion orientation properties, and T2 relaxation variations across these diffusion directions were explored. Results Diffusion‐PEPTIDE showed the capability to provide high quality diffusion images and T2 and maps from both protocols. The reconstructions were distortion‐free, avoided potential resolution losses exceeding 100% in equivalent EPI acquisitions, and showed tolerance to nearly 30° of rotational motion. Expected variation in T2 values as a function of diffusion direction was observed in the two‐compartment asparagus phantom (P < .01), demonstrating potential to explore diffusion‐PEPTIDE data for multi‐compartment modeling. Conclusions Diffusion‐PEPTIDE provides highly robust diffusion and relaxometry data and offers potential for future applications in diffusion‐relaxometry multi‐compartment modeling.
Source: Magnetic Resonance in Medicine
DOI: 10.1002/mrm.28579
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
Awards: Array-Compressed Parallel Transmission for High Resolution Neuroimaging at 7T, G2227408383, G3171611343, G393103480, The Human Connectome Project (HCP), Rapid MRI acquisition for pediatric low-grade gliomas, Computeserver Structural &Functional Image Analysis, fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution, Center for Functional Imaging Technologies, MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNER, A 3.0 Tesla MRI System in a Neuroscience ICU, A Storage Area Network for Structural and Functional Image Analysis, Next generation in-vivo diffusion imaging at submillimeter resolution, Silicon Graphics Prism Extreme 128P/1TB
OpenAlex ID: W3111992424