Work

Simulation-based assessment for N95 filtering facepiece respirator

Year: 2014
Type: dissertation
Abstract: N95 filtering facepiece respirators (FFRs) are most commonly used for personal protection from exposures to respirable aerosol particles. FFR comfort and fit are two important parameters for FFR designers, manufacturers, users, and standards developers. Although experimental approaches for assess FFR performance are useful for model validation they are time consuming and expensive. Due to the limitation of the laboratory equipment, the experimental measures may have large errors, and some results are not measurable. In the literature limited studies have been carried out on finite element analysis between headforms and respirators. Nobody has investigated air flow characteristics within the cavity between the headform and respirator to assess respirator performance. This study focused on developing simulation-based approaches for assessing FFR performance. The simulation methods include finite element (FE) method and computational fluid dynamics (CFD) method to study the contact pressure distribution and contact area determination between a headform and FFR with or without head movement, leakage, fit factor and CO2, relative humidity and temperature distributions in the FFR cavity. An FE simulation approach to simulation a deformable headform/FFR contact was developed. Contact pressures between the static headforms and the FFRs were determined by FE simulations, and were validated with experiments. A novel algorithm was developed to determine the contact areas between the static headforms and FFRs. The simulated contact areas were also validated by experiments. In addition, five motile headforms with the capability to move down (flexion), up (extension), and rotate left and right were developed and their movements were validated. FE simulations of motile headform-FFR combinations were conducted for five cases: a static head, flexion, extension, left rotation and right rotation. Contact pressures were determined in the key areas of the motile headform/FFR combination for the five cases. An CFD simulation approach for predicting the headform/FFR leakage was developed. The CFD method was used to calculate leak location(s) and “filter-to-faceseal leakage” (FTFL) ratio for ten headforms and six FFRs. The CFD simulation results were validated by thermal imaging videos from an infrared camera (IRC). An CFD simulation approach to evaluate FFR fit factor (fit of an FFR) was developed. Respirator fit was evaluated by a computer simulated fit factor (CSFF) defined as the particle concentration of the air flow passing through the injection plane to the particle concentration of the air flow inhaled by the nostrils. The particle sizes impacted the CSFF values, and the particle turbulent dispersion increased the CSFF values in each particle tracking simulations. Without the particle turbulent dispersion, the CSFF values increased with the increase of particle sizes. With the particle turbulent dispersion, the lowest CSFF value in the particle tracking simulations in each test appeared at the simulation with particle size 10 μm. The CFD approach was also used to determine CO2 and humidity distribution in the FFR cavity for four breathing cycles (19.2 s). The large CO2, relative humidity and temperature variations (CO2 mass fraction from 0 to 0.074, H2O mass fraction 0.0077 to 0.0151, and temperature 297K to 305K) for a breathing cycle in the FFR cavity were found. The CO2 and H2O mass fraction distributions in the FFR cavity were different among the test cases with different breathing openings. The inhaled CO2 mole fraction decreased with the increasing breathing flow rate. The highest temperature and relative humidity increased at the region the mouth and nostrils.
Author: Zhipeng Lei
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W3116082282
Cites: 131
Cited by:
Related to: 10