Year: 2018
Type: dissertation
Abstract: Inhaled airborne particles at work may cause adverse health effects, hence exposure to airborne particles needs to prevented.Moreover, the control of internal source released contaminants in the workplace is also emphasized for protecting the other persons working in or occupying adjacent areas from adverse biological and chemical exposure.The aim of the thesis was to find out practical and effective control methods for limiting the dispersion of particles from enclosed work environments: namely, the airborne infection isolation rooms (AIIRs) of hospitals and renovation sites.The containment of AIIRs were studied by measuring air change rates of the patient room and anteroom, pressure differences, contaminant removal, and contaminant transmission during door openings and human movement.A tracer gas method was used to simulate the release of infectious agents from a patient.Dust containment of renovation sites was studied by measuring pressure differences and dust concentrations (filter samples and real-time monitoring) simultaneously from the renovation sites and adjacent areas.In addition, the effect of using on-tool local exhaust ventilation in limiting the dust dispersion was investigated.This thesis also explored the airborne particle removal efficiency of a short-term water misting method.The method was applied after the work has been completed to limit the dispersal of airborne dust that has not been captured in real-time by source controls.Therefore, it is considered similar to a general ventilation method that dilutes the work-generated airborne dust concentrations.The airborne dust removal by shortterm water misting was assessed through experimental studies of dust decay and dust removal in the controlled laboratory environment.In addition, the feasibility of the method at renovation sites was studied.The findings of the thesis indicate that a high air change rate in AIIRs does not ensure efficient removal of infectious agents in the breathing zone of a healthcare worker (HCW).Instead, the local airflow patterns are more important.A high mean negative pressure between the AIIR and surroundings was shown to significantly limit particle transmission outside an AIIR.An anteroom aided in controlling the Universal Decimal Classification: 628.511, 628.8, 697.
Author: Anna Kokkonen
Institution: University of Eastern Finland
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
Award: G4619700066
OpenAlex ID: W3119314967
