Centrifugal Microfluidics for Extreme Point of Care Testing of Infectious Disease
Year: 2020
Type: dissertation
Abstract: In modern medicine, diagnosis dictates the clinical outcome. Point of care testing (POCT) technologies using microfluidics has fueled the evolution of modern In-vitro diagnostic technology with great sensitivity and precision while lowering sample volume, cost and time. In developed countries, POCT???s have decentralized reliable diagnosis from labs to home or at the bead side. This transformation has helped in preventing epidemics of infectious diseases and manage lifestyle diseases. However, every year millions of people die out of treatable illness and lack of diagnosis in developing parts of the world. A pressing need for technologies to bridge this gap existing but the extreme conditions of these geographies make it impractical for direct adaptation of existing POCT devices. This work identified the finest difference between the conventional POCT and extreme point-of-care testing (E-POCT) infrastructure and provide an insight into developing novel centrifugal microfluidic platforms that can meet the demand in these settings. Further, we demonstrate how these identified factors can be reiterated into developing new tools that can eventually be put to practical utility in E-POCT settings. \nWith our understanding of E-POCT settings, we conceptualized an idea to use a common toy-inspired low-cost instrument-free electricity-free POCT device ???diagnostic fidget spinner (Dx-FS)???. We describe the rationale behind the concept, the design, and the fabrication of the device. Our results show that Dx-FS device typically generates an angular rotational frequency ?? smaller than 300 rad/s with manual force. Taking advantage of this, a simple unit operation for sample enrichment was adapted in our device. In our initial experiments, the membrane with liquid-air interface (non-FAST) was tested and concluded insufficient to filter 1mL of sample. To achieve high filtration efficiency, we adopted a fluid-assisted separation technology (FAST), that significantly reduced membrane resistance thereby achieving efficient filtration even at varying angular velocity. Microscopic examination confirmed that the uniform spreading of bacterial cells on the porous filter intensity is 11.6 times higher for the FAST method. From experiments, we also confirmed that the optimized hydrodynamics in Dx-FS increases the effective concentration by over 100 times with few spins that directly impact the detection limit. \nWe then demonstrate the utility of Dx-FS as a diagnostic tool using E. Coli bacteria isolation and detection. We confirmed that bacterial concertation as low as 102 bacterial cells/ mL can be isolated using 0.45 ???m nitrocellulose membrane integrated within the device. Three different approaches were tested for detecting bacteria, Immunoaffinity with gold nanoparticle aggregation, Recombinase polymerase amplification (RPA) with lateral flow assay (LFA) and colorimetric detection using formazan. Though all three detection methods were promising, the colorimetric assay was integrated with the device and tested, so that it can be easily interpreted in the field and not require any cold storage. Our test with E.coli bacteria confirmed that Dx-FS along with the colorimetric assay can detect 103 to 108 CFU/ mL in 50 minutes. The effect of temperature, cellular contamination was verified and potential alternated were discussed in detail. \nUrinary tract infection (UTI) is a common disease across the world, leading to healthcare costs worth millions of dollars and affecting over 50% of women worldwide before they reach 32 years of age. For patients with clinical UTI symptoms, the standard diagnosis is based on pathogen detection using urine cultures. Unfortunately, the required infrastructure is absent in many rural areas; hence, clinicians resort to symptom-based diagnosis, which results in prescribing a broad-spectrum antimicrobial treatment for an unknown infection. Existing E-POCT tools like UTI dipstick tests are available but known to be less reliable than urine culture tests. This practice harms the patient???s healthy microbiome and leads to antimicrobial resistance. Combining with naked-eye detection, screening of bacterial load and identification are demonstrated. To validate our method, we tested urine samples from 39 urinary tract infection (UTI) suspects in Tiruchirappalli, India. Compared to the gold-standard culture method, which has a relatively long turnaround time, Dx-FS could provide a comparable answer on site in 50 min. \nCommon clinical intervention for community accrued UTI is an Empirical antibiotic prescription. Though two to three common antibiotics are recommended by guidelines, prescribing them without antibiotic susceptibility test (AST) puts the patient at risk of gaining resistance to most needed antibiotics. To answer this need, we further extended our scope and performed a rapid antimicrobial susceptibility test using Dx-FS (Fidget-AST) for two antimicrobial drugs, ciprofloxacin and cefazolin, within 120 minutes using 30 UTI patient isolates. The results confirm the possibility of using Fidget-AST in a resource-limited setting. \n\tOverall, this simple, hand-powered, portable device allows rapid enrichment of pathogens from human urine samples, showing high potential for future low-cost POCT diagnostic applications. This thesis provides a simple tool like Dx-Fs for UTI management and prevention of resistance in low resource settings. Some of the recent advancements on the platform have been also discussed in brief to demonstrate the future efforts of using the tool for other EPOCT applications.
Author: Issac Michael
Institution: Ulsan National Institute of Science and Technology
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W3120702185
