Extramedullary femoral alignment system in total knee arthroplasty: Accuracy in relation of severity and different types of varus
Year: 2021
Type: article
Abstract: OBJECTIVES: We assessed the accuracy of an extramedullary guide system for femoral component alignment in TKA. METHODS: We retrospectively analysed 87 total knee arthroplasties using a newly developed extramedullary guide system. RESULTS: Correct postoperative coronal plane femoral component, with deviation from neutral alignment by 3° or less, was found in 87% of the study population. The percentages were 100%, 91% and 79% for HKA of 0-3°, 3-10° and >10°respectively. CONCLUSION: The correct use of the extramedullary guide system allows the restoration of the neutral mechanical axes of the lower limb, especially in cases of limited varus deformity.
Source: Journal of Orthopaedics
Institution: Marche Polytechnic University
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W3130335837