Work

Multi-modal Fully-wireless Implantable SoCs for Interfacing with the Nervous System

Year: 2020
Type: dissertation
Abstract: This dissertation presents the design and implementation of two single-die inductively-powered current/voltage-sensing micro-stimulation systems-on-chip for interfacing with the central and peripheral nervous systems, respectively. The first design is a wireless implant for biochemical sensing in the brain at high spatial resolution by an array of 32×32 active sensors. Each channel employs an ultra-low-power 1st-order ∆Σ ADC for biochemical monitoring. Each of the 0.004mm2 current-sensing channels consumes 50nW of power and achieves 6-bits ENOB at 200Hz-bandwidth with less than a 100pA current sensitivity. The opamp-less ADC is analytically proven to be equivalent to conventional active ∆Σ-modulated ADCs, under conditions that are typical for biochemical microsensors. The SoC utilizes a 4MHz safety-optimized inductive-powering link for maximum power transfer under a given specific-absorption-rate constraint. The second system is an active probe and microstimulator SoC for interfacing with peripheral nerves. It performs 64-channel artifact-tolerant neural recording, cuff imbalance compensation by impedance sensing, and closed-loop neurostimulation. Each recording channel is a 2nd-order opamp-less ∆Σ ADC that consumes 140nW and occupies 0.01mm2 area in 130nm CMOS. The single-loop ∆Σ architecture achieves 2nd-order noise shaping with two passive integrators. This yields the lowest power and area for a 2nd-order ∆Σ ADC; and the lowest FOM (fJ/conv. step) among all state-of-the-art passive 2nd-order ∆Σ ADC (27fJ/conv. step). The SoC uniquely performs multi-modal input signal recording: voltage (for neural recording) and current (for impedance sensing) are measured concurrently using frequency multiplexing. The SoC also features a 60MHz energy-efficient inductive powering link and a 600MHz RF data communication link. The prototype is validated in vivo in the rat sciatic nerve for ENG sensing and for the correction of impedance-imbalance in cuff electrodes. A comprehensive optimization guide for efficient inductive links is then presented. The inductive power transfer link is studied by two different approaches: a power-efficiency approach where the powering link is optimized to achieve the highest-possible link efficiency, and a safety-optimized approach where the maximum possible power delivery is targeted. The two links are analyzed and optimized to find the optimal geometries of the on-chip coils that result in the highest powering-link efficiency and the highest delivered power, respectively.
Language: English
Open Access status: green
OpenAlex ID: W3131151937
Cites:
Cited by:
Related to: 10