Pre-Clinical Applications of a Forward-Viewing Intravascular Transducer for Sonothrombolysis.
Year: 2020
Type: article
Abstract: GOEL, LEELA DEVI.Pre-Clinical Applications of a Forward-Viewing Intravascular Transducer for Sonothrombolysis.(Under the direction of Xiaoning Jiang.) Deep vein thromboses affect over 300,000 people in the United States every year. Despite this common occurrence, thrombolytic drugs are often not effective for treating these types of blood clots, and mechanical thrombectomy poses risks for additional endothelial damage and clot particle formation. Therefore, there exists a need to improve treatments for deep vein thromboses. Sonothrombolysis refers to the use of medical ultrasound to improve blood clot treatment. This technique is often used to enhance thrombolytic drug treatment, such as with tissue plasminogen activator (tPA), or in combination with ultrasound contrast agents such as microbubbles (MBs), to mechanically disrupt clots. Previously, a forward-viewing intravascular (FVI) transducer with a sub megahertz center frequency was developed for sonothrombolysis applications. The advantage of this FVI transducer is the ability to directly insonate the clot of interest, minimize off target effects, and inject treatments directly onto the clot surface. In this research, the FVI transducer was applied for tPA mediated sonothrombolysis. We also demonstrated that the synergistic effect of combining tPA with microbubbles is dependent on the microbubble concentration used. In vitro clot lysis and passive cavitation experiments were conducted to study the effect of low dose tPA in FVI sonothrombolysis with varying MB concentrations. Enhanced FVI sonothrombolysis was observed in cases when US was combined with tPA or MBs compared to control, tPA alone, or US alone. The lysis rate of US + tPA + MBs was improved by up to 130%, 31%, and 8% for MB concentrations of 10 6 , 10 7 , and 10 8 MB/ml, respectively compared to MB + US alone. Changes in stable and inertial cavitation doses were observed, corresponding to changes in clot lysis in MB mediated FVI sonothrombolysis with and without tPA.Next, the use of low-boiling point phase change nanodroplets (ND) with the FVI transducer for sonothrombolysis was explored and then applied to treat retracted clots. One major challenge in current microbubble (MB) and tissue plasminogen activator (tPA) mediated sonothrombolysis techniques is effectively treating retracted blood clots, due to the high density and low porosity of retracted clots. Nanodroplets have the potential to enhance retracted clot lysis due to their small size and ability to penetrate into retracted clots to enhance drug delivery. In this study, the insonation parameters for nanodroplets were first optimized by determining the minimum peak negative pressure to induce cavitation with low-boiling point phase change nanodroplets for effective clot lysis in unretracted clots. It was found that 0.9 MPa was sufficient to induce stable cavitation of these low-boiling point phase change nanodroplets. Then, a retracted clot model was established, and nanodroplet mediated sonothrombolysis of retracted clots was studied in comparison to tPA and microbubble mediated techniques. The clot lysis as a percent mass decrease in retracted clots was 9 ± 8%, 9 ± 5%, 16 ± 5%, 14 ± 9%, 17 ± 9%,
Author: Leela Goel
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W3132673514