Work

Applications of Sweep Imaging with Fourier Transformation (SWIFT) : imaging brain microstructure and calcifications

Year: 2016
Type: dissertation
Abstract: Sweep imaging with Fourier transform (SWIFT) is a magnetic resonance imaging (MRI) technique with virtually simultaneous excitation and acquisition.This enables imaging of so-called short 𝑇𝑇𝑇𝑇 2 * components with extremely fast decaying signals.The aim of this thesis was to demonstrate the benefits of SWIFT for imaging the brain using both magnitude and phase contrast.A calcification in the brain forms because of disturbed energy metabolism in the tissue.These structures can be difficult to detect with MRI and hard to distinguish from e.g.hemorrhages since both cause a fast 𝑇𝑇𝑇𝑇 2 * decay.Reliable detection of calcifications would provide an additional way of assessing disease progression.In addition, the calcifications are known to be diamagnetic and likely to be visible in phase contrast.Hence, SWIFT magnitude and magnitude contrasts were applied to detect the calcifications formed after traumatic brain injury (TBI) as well as after epileptic seizures in animal models.Furthermore, since in the near absence of echo time, it could be thought that the SWIFT phase contrast is counterintuitive; therefore phase contrast was further evaluated in healthy brain tissue.Multiple properties of the contrast were examined in detail.The sensitivity of SWIFT magnitude contrast was evaluated further by measuring the magnetization transfer (MT) ratio with SWIFT to assess the integrity of the thalamocortical pathway in rats after a TBI with a comparison to diffusion tensor imaging (DTI).Importantly, a histological analysis of cell density (Nissl), myelin and iron (Perls') was conducted to clarify the results of the MRI assessment.SWIFT detected hyperintense and hypointense calcifications in the magnitude images, the latter being easily detected and distinguished from bleeding in the phase contrast image.The difference in magnitude contrast was related to the size of the granules forming the calcifications.The SWIFT phase contrast in brain structures was shown to be somewhat similar to conventional phase contrast, however, with crucial differences related to the spatial frequency content.Simulations and a separate MT experiment demonstrated a possibility for short 𝑇𝑇𝑇𝑇 2 * phase imaging.After TBI, and unlike the situation with DTI, MT-SWIFT revealed changes in all of the analyzed areas.According to the histological evaluation, the changes in the MT were mainly related to a loss of myelinated fibersThe results of this work may provide new methods for imaging healthy and diseased brain.Further studies will be needed to clarify the optimal way to exploit the short 𝑇𝑇𝑇𝑇 2 * sensitivity of SWIFT in brain imaging applications.
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W3133328899
Cites: 294
Cited by:
Related to: 10