Abstract: First of all, we would like to thank Dr Mowat and colleagues for their interest in our work [1]. The aim of our study was to investigate how cardiac output determined by the LiDCO plus™ device compared with the more frequently used thermodilution technique using a pulmonary artery catheter in patients with depressed systolic myocardial function requiring pharmacological support after heart surgery. Fortunately, only a small minority of cardiac surgery patients develop frank cardiogenic shock peri-operatively, which often necessitates installation of mechanical assist devices that will themselves interfere with cardiac output measurement techniques. Therefore, the setting we chose reflects a common clinical situation. We stated in the limitations of our paper that the results we obtained may not be applicable for patients with untreated heart failure. Nevertheless, our results indicate that thermodilution using a pulmonary artery catheter, when used for the sole purpose of cardiac output monitoring in the intensive care unit after cardiac surgery in this patient population, is probably comparable to the LiDCO system. Although there are reports that agreement between the pulmonary artery catheter thermodilution and LiDCO techniques decreases in high cardiac output states, our data as well as those of Hadian et al. show that accuracy actually improves in low cardiac output states [1, 2]. Regarding directional changes, the concordance we observed was 65%. Admittedly, the correlation between pulmonary artery catheter and LiDCO techniques is only moderate, but still better than those determined with other pulse contour techniques [2]. As the correlation coefficient is sensitive to data distribution with dependencies tending to be stronger if viewed over a wider range of values, the low magnitude of directional changes we observed might partially explain the poor correlation. Despite these shortcomings, the LiDCO system is the only pulse contour device that has been used successfully for goal-directed therapy [3, 4]. In this context, we do agree with Hadian et al. that the lower limits of blood flow-oriented goals for goal-directed therapy, given as an absolute number, should ideally be determined for each individual device, and probably cannot be derived by extrapolating data from other devices. Still, the question remains: can we trust pulmonary artery catheter values more than those obtained by the LiDCO system? Since the pulmonary artery catheter has its own limitations and is therefore not a gold standard, it is unclear which device better reflects true cardiac output in its various ranges. Until the issue is elucidated we will have to live with this uncertainty.
Source: Anaesthesia
Authors: B. Mora, M. Dworschak
Institution: Medical University of Vienna
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W3141579420