Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans.
Year: 1981
Type: article
Abstract: An acceptable method for measuring phasic coronary velocity and reactive hyperemia in humans has not been available.We have developed a doppler probe which can be coupled to surface coronary vessel* at the time of cardiac surgery with a small suction cup.Phasic coronary velocity can be measured with a signal to noise ratio that exceeds 20:1.Animal studies have shown that the probe does not alter myocardial perfusion or cause tissue damage.In addition, changes in mean coronary velocity are closely related (r « 0.97) to changes in coronary flow over a wide range (15-400 ml/min).The characteristics of reactive hyperemia in the coronary circulation of dogs determined with the doppler system are similar to those obtained simultaneously with an electromagnetic flow meter.Transient occlusions of branch coronary vessels in patients with normal coronary arteries are not associated with significant changes in heart rate, left atrial, or mean arterial pressure.The characteristics of reactive hyperemia in normal vessels of 13 patients were as follows: although reactive hyperemia responses were demonstrable following 1 to 2-aecond coronary occlusions, maximal responses usually occurred with 20-second coronary occlusions; following 20 seconds of coronary occlusion, the ratio of peak to resting velocity was 5.8 ± 0.6 (mean ± SE); the ratio of repayment to debt area was 3.1 ± 0.2, and the duration of the reactive hyperemia response was 20.8 ± 0.3 seconds.These studies provide the first quantitative measurements of coronary reactive hyperemia in humans. Circ Res 49: 877-891, 1981Although mean flow to the left ventricle can be assessed in patients with several techniques (Berne and Rubio, 1979;Klocke and Wittenberg, 1972), measurements of phasic coronary flow and reactive hyperemia in humans have been hampered by methodological problems.Three methods of measuring phasic coronary flow or velocity in humans have been described.Folts et al. (1979) measured phasic coronary flow by placing an electromagnetic flow meter around the proximal right coronary artery at cardiac surgery.Because this method requires surgical dissection of the coronary vessel, it has been employed infrequently.Cole and Hartley (1977) measured phasic coronary velocity with a doppler crystal mounted at the end of a catheter which could be placed in the left or right main coronary artery.This technique has not been widely used because velocity cannot be measured in branches of the coronary tree, a large bore catheter is needed, and the stimulus used to induce ischemia (injections of From the Cardiovascular Center and the Departments of Medicine, Surgery (Division of Thoracic and Cardiovascular Surgery) and Pharmacology and the Electrical Engineering Laboratory, University of Iowa and Veterans Administration Hospitals, Iowa City, Iowa.
Source: Circulation Research
Authors: M Marcus, C Wright, D Doty, C Eastham, D Laughlin, P Krumm, C Fastenow, M Brody
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W2075575242