Work

Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage

Year: 2011
Type: conference-paper
Abstract: This work proposes the zero sequence voltage component (ZSVC) of the stator three-phase voltages as a method for detecting winding inter-turns short circuits in permanent magnet synchronous motors PMSM operating under transient conditions. Additionally it proves the linear relationship between the\nZSVC and speed, which is effectively used as a fault severity index. The acquired ZSVC temporal signal is processed by means of the Hilbert-Huang transform (HHT).\nExperimental results presented in this work show the advantages of the method to provide helpful data for online diagnosis of stator winding inter-turn faults.
Language: English
Open Access status: green
OpenAlex ID: W3144658306
FWCI: 3.146
Cites:
Cited by: 19