Work

Nâng cao độ tin cậy của biến tần đa mức cấu trúc cầu H nối tầng trong hệ truyền động cho động cơ không đồng bộ

Year: 2020
Type: article
Abstract: To increase the reliability of electrical drives system FOC-IM which is supplied by the cascaded H bridge multilevel inverters in faulty conditions, this paper uses new detecting method based on the differences between output voltage and control signal of each H bridge, and proposes new improved SVM algorithm for cascaded H bridge multilevel inverters when the open-circuit problem occurs. By analyzing the effect of the faulty H bridge, the switching states that creating standard voltage vectors are chosen precisely to achieve following objectives: Output voltage is maximum, three phases are balanced, and the common mode voltage is optimized. This algorithm can be applied to H bridge inverters at any level. Besides, the affect of the open-circuit issues is evaluated with and without proposed algorithm, based on the simulation results of electrical drives system FOC-IM model supplied by 11-level cascaded H-Bridge Inverters on MATLAB – Simulink.
Language: Vietnamese
Open Access status: diamond
OpenAlex ID: W3150394397
FWCI: 0.073
Cites: 20
Cited by: 1
Related to: 10