Strahleninduzierte DNA-Doppelstrangbrüche nach Herzkatheteruntersuchungen

Year: 2020
Type: dissertation
Abstract: Objectives Cardiac catheterization procedures are increasingly used in modern medicine for diagnosis and treatment of cardiovascular disease. A limiting factor is the often considerable x-ray dose delivered to the patient and the personnel. Physical dosimetry involving ionization chambers and phantom devices are commonly used to monitor dose exposure. These methods allow an estimation of radiation exposure but do not consider individual factors or biological response to radiation exposure. DNA double-strand breaks (DSB) represent one of the most relevant radiation-induced lesion. In case of misrepair, DNA-DSB are able to induce cancer. The aim of this study was to evaluate radiation-induced DNA-DSB after cardiac catheterization from patients and personnel to approach an application of biological dosimetry. Design and Methods Blood samples for in-vivo experiments were taken before and after cardiac catheterization from 38 patients and from 2 cardiologists. Additionally, in-vitro experiments were performed with blood samples taken from healthy volunteers. With γ- H2AX immunofluorescence analysis DNA-DSB were visualized as foci and quantified. In-vivo findings were related to corresponding results of in-vitro analyses. Observations and Results Radiation doses ranged from 117 to 1797 mGy, dose area products from 924.1 to 9596.1 μGym2 and fluoroscopy times from 1 to 14 minutes. A radiation-induced augmentation of DNA-DSB could be seen in every patient, the evaluated foci after cardiac catheterization ranged between 0.48 and 1.08 excess foci/cell. These foci decreased after 15 minutes to a range of 0.43 to 0.86 excess foci/cell. There was no radiation-induced increase of DNA-DSB in cardiologists during an ordinary working day. In-vitro experiments revealed a better approach to real in-vivo findings in cardiac catheterization using a fractionated radiation with 10 x 5 mGy in comparison to a single radiation with 50 mGy. Kinetics of DNA double-strand repair were simulated with blood samples from healthy volunteers during a period of 210 minutes. Conclusions The γ-H2AX immunofluorescence microscopy represents a suitable tool to measure DNA DSB in patients undergoing cardiac catheterization procedures and thus can be used for biological dose assessment supplementary to conventional physical or mathematical dosimetry.
Language: German
Field: Medicine
Open Access status: green
OpenAlex ID: W3156286599
Cites: 160
Cited by:
Related to: 9