Work

Comparative Animal Study of Healon and Hyal 2000.

Year: 1998
Type: article
Abstract: We compared Healon® which is widely used as a viscoelastic with Hyal 2000®, recently produced in Korea. We evaluated anterior chamber reaction, intraocular pressure, and specular microscopy after injection of 0.2ml Healon and Hyal 2000,respectively, into anterior chamber of 20 cats, and performed light microscopy and scanning electron microscopy 8 weeks later. We calculated the corneal swelling rate after 0.2ml Healon and Hyal 2000 were coated on the corneal endothelium of 10 rabbits and GBR solution with 0.5mM H202 was perfused. Anterior chamber reaction disappeared after 2 days of injections, and intraocular pressure (IOP) increased after 6 hours of injection but normalized after 24 hours in both 2 groups. Corneal endothelial cell count was 4956cells/mm2 in the Healon group and 5021cells/mm2 in the Hyal 2000 group on the first post-injection day, and 4827cells/W and 4810cells/mm2 1 week later, without a statistical difference. The histologic abnormality was not detectable in light microscopy or scanning electron microscopy in both groups. The corneal swelling rate with Healon was 15.85 µm/hr and 12. 72µm/hr with Hyal 2000, while it increased to 69.29µm/hr and 67.51µm/hr in controls (p<0.05), respectively. The clinical findings showed no difference and histologic findings appeared normal in both the Healon and the Hyal 2000 groups. The inhibitory effect on the corneal swelling was similar during in vitro perfusion in both groups
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: green
OpenAlex ID: W2565574169
FWCI:
Cites:
Cited by:
Related to: 10