An assessment of indoor and outdoor air quality in a university environment : a case of University of Limpopo, South Africa
Year: 2020
Type: dissertation
Abstract: Air pollution of late has been the focus of many studies due to the detrimental health risks \nthat it poses to individuals. University environments have several academic departments \nwith peculiar activities that could be affecting the indoor and outdoor air quality (AQ) of \nthese environments. University settings differ from other environments because of the \nvariety of activities and different lines of work that go on inside buildings housing academic \ndepartments and their surroundings, which are likely to have an impact on indoor air \nquality (IAQ) and outdoor air quality (OAQ) in this environment. Only a few AQ studies \nhave been done in university sites and surrounds worldwide and in these studies, IAQ \nwas given primary importance; whereas, the outdoor environment was and is often \nneglected. A study comparing both IAQ and OAQ is critical to further understand the \nrelationship between IAQ and OAQ within a university campus. The University of Limpopo \n(UL) in the Mankweng township of South Africa has been undergoing some \nrefurbishments with numerous construction activities going on in addition to the academic \nactivities of UL. These activities may be affecting the AQ in this unique environment. The \nmain aim of this study was to determine differences between indoor and outdoor AQ in a \nuniversity environment and to understand how AQ in this unique environment varies with \nseasons and building function. The study was carried out in three buildings housing three \ndifferent academic departments in UL namely: Department of Physiology and \nEnvironmental Health (PEH), Department of Biochemistry, Microbiology, and \nBiotechnology (BMBT) and the Department of Biodiversity (BIOD). Twenty indoor and 20 \noutdoor measuring sites were identified per departmental building from where real-time \nmeasurements of 11 AQ parameters (linear air velocity (LAV), dry-bulb temperature (Tdb), \nrelative humidity (RH), carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), sulphur \ndioxide (SO2), nitrogen dioxide (NO2), hydrogen sulphide (H2S), non-methane \nhydrocarbons (NMHCs) and volatile organic compounds (VOCs)) were taken over three \nconsecutive days per season. Thus, a total of 60 indoor and 60 outdoor measurements \nwere taken for each parameter in each of the three buildings of interest per season, \nleading to 360 measurements per season and 1440 measurement per parameter over the \none-year period of study across the study area. A hot-wire anemometer was used to \nmeasure LAV, whereas the Q-Trak indoor AQ monitor was used in the measurement of \nTdb, RH, CO and CO2. Aeroqual AQ monitors were employed in the measurement of O3, \nSO2, NO2, H2S, NMHCs and VOCs. The Wilcoxon signed ranks test was used to determine differences between indoor and outdoor environments. Significant differences \nwere found between the indoor and outdoor environments for LAV (all three buildings), \nTdb (PEH and BMBT), RH (BIOD), O3 (all three buildings), NO2 (all three buildings), CO \n(all three buildings), CO2 (all three buildings), NMHCs (BMBT and BIOD), and VOCs (all \nthree buildings) (p < 0.05). Linear air velocity, O3, SO2, CO, CO2, and H2S \nvalues/concentrations across the indoor/outdoor environments were within the \nASHRAE/DEA/WHO guidelines/standards, whereas Tdb, RH and NO2 \nvalues/concentrations were not. Air quality in the study area varied with building, with the \nbest AQ across both the indoor and outdoor environments being within the BIOD building, \nwhilst the worst AQ across both environments was encountered in the PEH building. \nSeasonal differences between buildings were also identified between indoor and outdoor \nenvironments among the PEH, BMBT and BIOD buildings (p < 0.008). Across the indoor \nenvironment, the winter season was found to be the season with the best AQ, since all \nthe pollutants were found at minimum concentrations. Factors affecting AQ in the study \narea included thermal comfort, occupant densities, building function, laboratory \nemissions, renovation activities, generators, vehicular emissions, among others. The best \nAQ across the outdoor environment occurred during the autumn season, since all the air \npollutants were present at minimal concentrations during this time. The best predictors of \nLAV, Tdb, CO, CO2, NO2, and NMHCs were seasons (R2 = 1.000, p < 0.01). For the \nparameters RH, H2S, and VOCs, the best predictor was building type (R2 = 1.000, p < \n0.01). The indoor and outdoor environment were the best predictors for SO2 (R2 = 0.999, \np < 0.01). Ozone had no single predictor that was found to significantly influence its \nconcentration in this study. In relation to an air pollution index (API), generally all pollutant \nindices fell within the fair, good to very good range when using mean and maxima \nconcentrations, whereas, corresponding NO2 concentrations throughout the study fell \nwithin the poor to very poor range (105.660–250.000). University management should \ntake into consideration ventilation in laboratories, occupant densities and location of \nstandby generators and car parks in the management of AQ on the university campus. All \nheating, ventilation and air conditioning (HVAC) systems need to be upgraded and work \nin tandem with natural ventilation when having high occupant densities within buildings. \nFuture studies in this sector could incorporate larger sample sizes, be designed as a \nlongitudinal study, and make use of questionnaires and sample more AQ parameters to \nget a detailed understanding of a university site and its surrounds.
Author: Antony Jino Mundackal
Institution: University of South Africa
Language: English
Subfield: Health, Toxicology and Mutagenesis
Field: Environmental Science
Domain: Physical Sciences
Keywords: indoor air quality, outdoor air quality, university campus, seasonal variation, building function, construction activity, volatile organic compounds, non-methane hydrocarbons, carbon dioxide, nitrogen dioxide, sulfur dioxide, ozone, carbon monoxide, hydrogen sulfide, air velocity, relative humidity, dry bulb temperature, University of Limpopo, Mankweng, university buildings, air pollution
Open Access status: green
OpenAlex ID: W3176600166
