Work

EMC Specific Problems of Frequency Converters Used at Interlocking Device

Year: 2009
Type: article
Abstract: . The paper deals with problems of electromag-netic compatibility (EMC) of frequency control drive of electromotive switch actuator of railway switch. The fre-quency converter with Pulse Width Modulation (PWM) and the output sinus filter are used for feeding of the asynchro-nous motor of the switch actuator. This drive is operated in an insulated system of feeding voltages. The drive is fed by a frequency converter with an unshielded cable with length up to 1.2 km. The EMC problems occurring at development and operating of the drive are analyzed in this paper. The used solution of these problems and experience with EMC of the given system from real operation are described in this paper as well.
Language: English
Open Access status: green
OpenAlex ID: W3185796331
FWCI: 0.675
Cites: 3
Cited by: 8
Related to: 10