Work

Study of timing properties of multi-pixel-photon-counter's illuminated by 630 nm and 405 nm PiLas laser light

Year: 2009
Type: article
Abstract: Timing measurements of Multy-Pixel-Photon Counters (MPPC's) at the picosecond level were performed at Fermilab. The core timing resolution of the amplifiers, discriminators and TAC/ADC combination to perform these measurements is approximately 2 picoseconds. The single photoelectron time resolution (SPTR) was measured for the signals coming from the MPPC's. An SPTR of about one hundred picoseconds was obtained for MPPC's illuminated by picosecond laser pulses. The SPTR depends on applied bias voltage and on the wavelength of the light. A simple model is proposed to explain the difference in the SPTR for blue and red light. Finally, requirements for the MPPC's temperature and bias voltage stability to maintain the time resolution are discussed.
Language: English
Open Access status: green
OpenAlex ID: W319690476
FWCI:
Cites: 2
Cited by:
Related to: 10