Work

A Validated Methodology for the Forensic Toxicological Analysis of Opioids in Biological Fluids Using Solid Phase Extraction, Microwave Derivatization and Gas Chromatography-Mass Spectrometry

Year: 2019
Type: dissertation
Abstract: The development of the present study became pertinent due to the misuse of opioids and the number of overdose deaths associated with its use, both in Portugal and in the rest of the world. On the other hand, being the use of alternative biological matrices to postmortem blood, an area of growing interest in forensic toxicology, we studied the feasibility of using pericardial fluid in the determination of the selected substances.Thus, the objective of this work was the development, optimization and validation of an analytical methodology for the qualitative and quantitative determination of some opioids in blood and pericardial fluid.The opioids studied were: morphine, codeine, 6-acetylmorphine, 6-acetylcodeine, oxycodone, oxymorphone and fentanyl.The study included the optimization of the analytical procedure and the chromatographic method. We have optimized solid phase extraction (SPE), derivatization with and without 1% aqueous hydroxylamine and microwave derivatization time with the chemical reagent MSTFA (n-methyl-n-(trimethylsilyl) trifluoroacetamide)+5% TMCS (trimethylchlorosilane).The most efficient and selective method was as follows: precipitation with acetonitrile of 250 μL volumes of blood and pericardial fluid samples, derivatization of the substances of interest using 1% aqueous hydroxylamine in PBS (1:2, v/v) with microwave action for 30 seconds with a power of 900 W at 50%. The samples were cooled and then the analytes of interest were extracted by SPE. After evaporation of the eluates (under nitrogen stream at 40 °C) the extracts were derivatized with MSTFA+5% TMCS under microwave action for 100 seconds with a power of 900 W at 100%. Then the derivatized extracts were injected (2 μL, splitless) directly into a gas chromatography mass spectrometry system (GC-MS-EI) with selective ion monitoring mode (SIM mode) and with the oven at the initial temperature of 50 °C.After optimization, the method was validated following the standards of the Scientific Working Group for Forensic Toxicology (SWGTOX) to ensure that the method is suitable for its intended purpose and thus attest to its reliability in interpreting the analytical results. The method presented linearity in the range 5-1000 ng/mL with coefficients of determination above 0.99 for all analytes. The limits of detection (LOD) ranged from 3 to 4 ng/mL, depending on the substance and/or matrix analysed and the limits of quantitation (LOQ) were 5 ng/mL for all substances. Regarding the precision (intra-day and intermediate) all concentration levels presented CV values <20% and the bias was within ±20%. It was also verified that the substances presented stability under the following conditions: in the extracts left in the autosampler under environmentalconditions for at least 24 h; blood and pericardial fluid samples on the workbench for 4 h; pericardial fluid samples for 3 freeze-thaw cycles for at least 4 weeks.Finally, the analytical methodology was applied to real samples provided by the Serviço de Química e Toxicologia Forenses da Delegação do Centro do Instituto Nacional de Medicina Legal e Ciências Forenses, I.P. (Forensic Chemistry and Toxicology department of the Centre Branch of the National Institute of Legal Medicine and Forensic Sciences, I.P.).According to the literature review, this was the first method developed for the simultaneous detection and quantification of this group of substances in blood and pericardial fluid using microwave induced derivatization with the chemical reagent’s hydroxylamine and MSTFA+5% TMCS.
Language: English
Subfield: Toxicology
Open Access status: green
OpenAlex ID: W3200330437
Cites: 126
Cited by:
Related to: 10