Work

Demonstration of Energy Efficiency Potential; Literature review of benefits and risks in domestic retrofit practice and modelling

Year: 2021
Type: book
Abstract: Airtightness Improvements: Excessive infiltration undermines the energy performance of homes and retrofits.While the housing stock average airtightness levels may be around 11.48 m 3 /h/m 2 @ 50 Pa (slightly worse than new build limit) research studies have found examples of extreme air leakage in particular house types (e.g.steel frame homes) and linked to particular building characteristics (e.g.unsealed dry lining and suspended timber floors).Retrofits often include airtightness improvements, however, its contribution to energy efficiency as an individual retrofit measure is not well understood.DEEP will undertake airtightness testing to evaluate air leakage in a range of housing archetypes.It will also undertake BPE before and after airtightness-specific retrofits to quantify how these can reduce the heat loss from homes.Building energy models will also evaluate how airtightness may undermine other retrofits. Ground Floor Insulation:Ground floor retrofits are rare despite there being around 10 million uninsulated suspended timber ground floors and evidence suggesting insulating these could reduce heat loss in homes by up to 20%, depending on how much infiltration is taking place through the ground floor.DEEP will survey existing uninsulated and insulated floors to identify any barriers to installation or performance issues.When installing thermal upgrades, DEEP will undertake before and after BPE on a range of ground floor retrofits to explore the potential performance and identify possible risks related to moisture build-up in the under-floor void.Multiple Measure and Deep Retrofits: Although multiple measure and deep retrofits can achieve greater savings than single measures, they are rare, meaning homes tend to have piecemeal retrofits spread over many years.How multiple measures combine to reduce heat loss is not well understood, though deep retrofits have been observed to reduce heat loss in homes by over 50%.It is not well understood how retrofit measures are currently designed and installed to interact, or how the risk of condensation and moisture accumulation are affected , when measures are installed in combination.DEEP will undertake several phased deep retrofits on a range of solid wall homes to replicate current practice and to understand the contribution of each individual measure's contribution to the whole system performance.This will identify mitigation strategies to reducing risk during these piecemeal retrofits and compare performance when undertaking a deep retrofit all at once.Modelling will also be used to identify which approach suffers from the largest performance gap and to quantify the risks to households, such as increased surface condensation risk.Following this review of retrofit measure performance, it appears there are knowledge gaps around the following specific heat loss mechanisms:• Insulated elements not effectively interfacing (e.g.loft and cavity wall insulation);• Discontinuities in insulation (e.g.where obstructed by services or building features);• Thermal bypasses and air looping around insulation; and• Infiltration affected by, and its effect on, other retrofit performance.Additionally, knowledge gaps have been particularly evident for the following retrofit types and scenarios:• Less common retrofits (e.g.ground floor, room in roof and airtightness retrofits);• Piecemeal versus deep retrofit performance; and• Inter-house and whole-house considerations for single measure retrofits.Retrofit modelling techniques and input assumptions have also been reviewed in this project and the following main issues have been highlighted:Whole building modelling: Reduced data Standard Assessment Procedure (RdSAP) is a steady-state model used to predict retrofit performance for policy via Energy Performance Certificates (EPCs).However, its input data is not detailed and often fixed to default assumptions, and this reduces the accuracy of its predictions.Steady-state models that allow for more detailed inputs and dynamic simulation models (DSM) are more accurate.DEEP will explore which RdSAP inputs and default assumptions could be improved to make RdSAP more useful for retrofit evaluations.Building fabric in whole building modelling: Default U-values, y-values and infiltration assumptions in RdSAP have a large influence on the model's accuracy.DEEP will validate existing defaults and define uncertainty in these where possible.Modelling overheating risk: Retrofitting homes affects overheating risk which may be more problematic as the climate warms.DEEP will evaluate the usefulness of the SAP summergains-check and compare this with alternatives used in PHPP and DSM analysis.Occupancy and internal heat gains: Occupant behaviours (including heating hours and heating set points), and the level of internal gains generally, are fixed in RdSAP, thus the impact of different occupant types on retrofit payback cannot be assessed in these calculations.DEEP will predict the extent to which RdSAP over or underestimates the performance of different retrofits for different occupant types.Weather files used in models: Full SAP models can use localised, postcode-specific weather data whereas RdSAP is limited to 21 UK regions.The impact of this on model accuracy, as well as the impact of using hourly weather data in DSM, will be evaluated in the DEEP project. U-Values:RdSAP uses default U-values based on building characteristics, which is one of the largest areas of uncertainty in the calculation.DEEP will explore the benefits of having a wider range of defaults for RdSAP assessors to identify. Thermal bridging:In homes with lower heat loss, the relative proportion of heat loss via bridges increases.Additionally, retrofits can introduce new bridges into homes via discontinuities in insulation.Thus, changes in thermal bridging in post retrofit models may be particularly important.However, it is not clear if bridging defaults in RdSAP reflect this reality.DEEP will undertake modelling of thermal bridging pre-and post-retrofit in a range of different house archetypes and retrofit types to estimate what defaults may be more appropriate for use in RdSAP calculations.It will also undertake thermal bridging modelling to quantify the risk of surface and interstitial condensation that may occur in common retrofit scenarios.Hygrothermal Behaviour: Models which predict water accumulation and risk of rot in construction fabric use databases of materials with assumed properties of density, porosity and water content, etc. which affects the accuracy of the model predictions.Data from field measurements can be collected to improve accuracy but is costly and time consuming.DEEP will undertake testing of common UK wall types to widen the range of defaults for modellers to choose from and evaluate how sensitive model predictions are to different material properties.DEEP will also use hygrothermal simulations to undertake scenario analysis for common retrofit scenarios to quantify risk of moisture accumulation.This publication is available from: https://www.gov.uk/government/publications/demonstration- of-energy-efficiency-potential-deep If you need a version of this document in a more accessible format, please email [email protected].
Language: English
Open Access status: green
OpenAlex ID: W3204939775
FWCI: 4.957
Cites: 162
Cited by: 21
Related to: 9