Abstract: One field of application for the cone beam computed tomography (CT) is the dimensional measurement of components as e. g. cast parts by means of a nominal/actual-value comparison. The interpretation of the measured data is impaired due to the artefacts typical to industrial CT. The Iterative Artefact Reduction (IAR) represents an effective method for homogeneous components. This thesis presents the Synchronous Artefact Reduction (Einsatzsynchrone Artefakt Reduktion EAR), a new correction concept, that is based on the IAR to some extent. The use of the available nominal volume expedites the artefact correction ompared to the IAR. For this purpose the nominal volume has to be registered during the data acquisition via some 2D-X-ray projections. The registered volume can be used for the simulation of length projections which are then related to the intensities. In order to be able to dispense with an initial knowledge on the sought transformation the registration is separated into a global and a local phase. The former uses barycentral lines to determine the translation. The rest of the registration is performed intensity based. In oder to obtain an appropriate merit function this thesis introduces the concept of the Total Catchment Area (Absoluten Einzugsbereich AEB). Current 2D-3D-merit functions are compared to this AEB-property and to the precision of the realised registration results which results in the use of Normalised Mutual Information.
Author: Matthias Franz
Institution: Friedrich-Alexander-Universität Erlangen-Nürnberg
Language: German
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W3208655856