NOise reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing
Year: 2020
Type: article
Abstract: Diffusion-weighted magnetic resonance imaging (dMRI) has found great utility for a wide range of neuroscientific and clinical applications. However, high-resolution dMRI, which is required for improved delineation of fine brain structures and connectomics, is hampered by its low signal-to-noise ratio (SNR). Since dMRI relies on the acquisition of multiple different diffusion weighted images of the same anatomy, it is well-suited for denoising methods that utilize correlations across the image series to improve the apparent SNR and the subsequent data analysis. In this work, we introduce and quantitatively evaluate a comprehensive framework, NOise Reduction with Distribution Corrected ( NORDIC ) PCA method for processing dMRI. NORDIC uses low-rank modeling of g-factor-corrected complex dMRI reconstruction and non-asymptotic random matrix distributions to remove signal components which cannot be distinguished from thermal noise. The utility of the proposed framework for denoising dMRI is demonstrated on both simulations and experimental data obtained at 3 Tesla with different resolutions using human connectome project style acquisitions. The proposed framework leads to substantially enhanced quantitative performance for estimating diffusion tractography related measures and for resolving crossing fibers as compared to a conventional/state-of-the-art dMRI denoising method. Highlights We propose a framework, NORDIC, for denoising complex valued dMRI data using Gaussian statistics The effectiveness of the proposed denoising method is distinguished by the ability to remove only signal which cannot be distinguished from thermal noise The proposed method outperforms a state-of-art method for denoising dMRI in terms of fiber orientation dispersion Quantitative evaluation of NORDIC across different resolutions and SNR using human connectome type acquisitions and analysis shows up to 6 fold improvement in apparent SNR for 0.9mm whole brain dMRI at 3T.
Source: NeuroImage
Institution: University of Minnesota
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,000
Awards: G3701513713, G585115172, G6671297155, CAREER: Geometric Techniques for Big Data Medical Imaging, Elementary Neuronal Ensembles to Whole Brain Networks: Ultrahigh Resolution Imaging of Function and Connectivity in Humans, G9000013873, G9000308991, Technology to Realize the Full Potential of UHF MRI
OpenAlex ID: W3101545983
