Abstract: The goal to reduce the energy demand in the built environment applies also on listed buildings with special architectural and societal values.However, the possibilities of retrofitting façades of listed buildings are rather limited.This study concerns a 1930s multi-family building in Gothenburg where the ground floor is composed of 340 mm structural brick and the two upper floors of 80 mm structural timber walls.The façade is externally retrofitted using 20 mm Vacuum Insulation Panels (VIP), covered by 30 mm glass wool boards, which give a calculated reduction in U-value of 64%.Measurements of temperature and relative humidity in the wall from the period January 5 to March 22, 2011, are analyzed for the brick wall.The analysis show improved hygrothermal conditions compared to the case in a reference wall.