Summer comfort in a low inertia building with a new passive cooling system using thermal phase-shifting

Year: 2011
Type: book-chapter
Abstract: This study aims to evaluate the thermal behaviour of a new passive cooling system working with a non-continuous pattern. The research is based on numerical studies and experiments performed on the full-scale phase shifter which was designed and installed at CSTB (Scientific and Technical Centre for Building research), a French building research center. In the first part of this study, we describe a model implemented on the SimSpark simulation platform. The validation phase is in two parts: first, we validate the implementation against the analytical solution for constant airflow and harmonic temperature profile: then we use experimental data to assess its predictive capability with an intermittent airflow pattern. The second part focuses on the optimisation of the system considering the stop and start times and the quantity of storage material. To investigate its efficiency, two indexes were proposed and computed; one concerns the environment cooling potential and the other the energy storage efficiency which represents its capability to transfer nocturnal potential into daytime potential. The environmental evaluation shows an optimal relations between stop and start times start exist in order to maximise the mean cooling potential. For non-continuous airflow, the energy storage efficiency index shows that a reduction in the daily must be combined with a reduction in the material storage volume. Finally, simulations were done for an experimental building with very high energy efficiency (INCA, INES, le Bourget-du-lac, France) for several strategies. The results in terms of summer thermal comfort show that intermittent with optimised work periods is an interesting alternative to the more usual continuous ventilation. The choice of appropriate periods of operation permits a damping of the daily temperature swings so that the behaviour approaches one of a high-inertia building. INTRODUCTION Low inertia buildings are subject to internal higher daily temperature swings than more massive buildings and this usually leads to thermal discomfort. In the summer, the low thermal storage of these buildings makes passive cooling strategies such as nocturnal inappropriate, because they increase the day/night temperature difference. In order to use this free cooling potential, we propose the use of thermal mass by associating an air/mass storage system called ventilation to the HVAC building system[1]. The aim of the phase-shifted is to delay the input temperature signal without damping it[2]. Our work consists of reducing the system’s size and electricity consumption to optimal levels. NUMERICAL MODEL The physical phenomena that take place in thermal phase-shifting are similar to those in a packed bed. A mechanically induced air flow passes through storage elements that are homogeneously distributed within a duct with cross section S and length L. The void fraction is defined as η = (1−Vb/V ). The two-phase model is based on the following assumptions: • Temperature in each storage element is homogeneous (lumped capacity models). • The arrangement of the storage elements, air flow and convective coefficient are independent on the cross-section and along the length of the system. • Axial heat transfer is negligible. • The ducting is totally adiabatic. These assumptions lead to the two-phase Schumann model [8] in which equations represent the energy balance on air and on material. This system is numerically solved using the finite volume method on a SimSpark platform [6]. Equations for the ith control volume are presented below: Cpaṁa (Tei −Tsi) = Abihci (Tai −Tbi)+ρaCpaVadtTai (1) Abihci (Tai −Tbi) = ρbCpbVbdtTbi (2) Tai = (Tei +Tsi)/2 (3) To confirm that the implementation is correct and the discretisation sufficient, the model was compared to the analytical solution of Zgraggen [9]. The validation concerns the air temperature outlet in the case of harmonic excitation (Ta = θcos(wt)) and constant air flow. Further investigation has been done on model validity with non-constant airflow using the prototype presented below. PROTOTYPE DESCRIPTION AND EXPERIMENTAL VALIDATION fan 1000 500 3500mm 50
Language: English
Open Access status: green
OpenAlex ID: W369607274
FWCI:
Cites: 5
Cited by:
Related to: 10