Work

Failure Analysis of Cold Evaporator for Liquefied Nitrogen.

Year: 1994
Type: article
Abstract: On August 28, 1992, a terrible explosion occurred at a cold evaporator for liquefied nitrogen at the Ishikari plant of Suzuki Sogo Shokuhin Co. Disruptive failure of pressure vessels generated high-speed projectiles. The maximum extent of the zone affected by these projectiles was about a 350 m radius. The cause was pressure increase due to locking of original valves of safety valves. The cause and process of disruptive failure of pressure vessels were analyzed.
Language: English
Open Access status: diamond
OpenAlex ID: W2313346035
FWCI:
Cites: 1
Cited by: